____________________________________________________________________________________
____________________________________________________________________________________
Speeder X1 and X2 Configuration and API Guide
Page 12/36
D00000 refers to a failed distance measurement in the case of which the amplitude value
carries an error code. The Code is given only if the Amplitude Output is Enabled (Control
Byte 2, Bit 3 = 1).
Error messages in ASCII distance measurement mode:
Hex value Dec val. Error
1
1 EEPROM R/W error
2
2 No object
4
4 Receiver error
8
8 TDC counter error 1
10
16 TDC counter error 2
20
32 Low battery
40
64 Supply voltage
80
128 Invalid value
100
256 Unknown command
200
512 TDC counter error 3
400
1024 EEPROM or FLASH Checksum error
800
2048 Voltage error
1000
4096 APD voltage error
2000
8192 Temperature
4000
16384 Power consumption
8000
32768 High Voltage error