____________________________________________________________________________________
____________________________________________________________________________________
Speeder X1 and X2 Configuration and API Guide
Page 32/36
37
B
Speed Limit
If the speed limit is zero, hardware triggering is
given always when a vehicle is detected. If the
speed limit is set, the triggering is given out
only for speeding vehicles.
NOTE! The unit is [km/h] even if bit 2 of
parameter 26 is set!
km/h
0 - 255
39,40
W
Vehicle Height Limit
Setting up height limit for Speed Limit Large,
parameter 36.
The height value is the difference between the
shortest measured value from the vehicle and
the far end of the triggering window.
For example, in a set-up where the sensor
locates 6 metres above the road and the
maximum distance to vehicles is 30 metres, a
2-metre height limit means a value of 1000 cm.
But as the measurement window does not
reach the surface of the road, typically a value
of approximately 750 is used.
The user may check the actual height values of
different vehicles by enabling ‘Height’
measurement by bit 7 of parameter 26 and
making some test speed measurements.
cm
200 - 1000
43
B
Trigger Window End for Multiple Lanes
Defines the maximum distance needed to
cover two or more lanes.
m
1 - 255
44
B
Direction Change Distance
Defines a distance after which the direction of
vehicles is opposite.
Driving direction of the first lane is defined by
bit 5 (Speed Behind) of parameter 2.
m
0 - 255
46
B
Speed Verification distance
Defines a distance where trigger will occur (if
not zero). (See Chapter 4.1.2)
cm
0 - 255
47
B
LaserControl
Select laser in use; 0 = Beam B, 1 = Beam A,
2 = toggle between laser. This selection
applies in operation modes 0 and 1.
0,1,2
2
48
W
Ground distance. Ground level distance
measured with the sensor. Applies when snow
measurement is activated.
cm
0 - 38000
0
50
B
Control Byte 4 (See Chapter 6.7)
51
B
Control Byte 5 (See Chapter 6.8)
52
B
Control Byte 6. Consult manufacturer for
changes. Otherwise ignore (keep default value)
128
53
B
Sensor Orientation
Select sensor orientation: 0 = detection on
automatic setting of measurement window, 1 =
laser sticker up, 2 = laser sticker down.
0,1,2
1
Note: The parameters return to values saved into the permanent memory at power-ON.