background image

4

NookBox

Installation Guide

AC Powered Indoor Siren 

Features

Alarm Activation

When an alarm is activated, the Indoor Siren will sound continuous alarm and the LED indicator will flash continuously while the siren is 
alarming. If the alarm system control panel has programmed alarm duration, the Siren will be activated according to panel alarm length. 
If the alarm system does not have alarm duration programmed, the Siren will be activated for 3 minutes. 

•  The Siren can be enable/disable to sound a door chime by the Control Panel.

Audio Indication

The Indoor Siren emits different audio indication & voice prompts according to different status of the security system as listed table below:

Condition

Audio Indication

Alarm

Continuous alarming

Panel enters Arm Mode

Voice prompt: “Away Arm”

Panel enters Home Mode

Voice prompt: “Home Arm”

Panel enters Disarm Mode

Voice prompt: “Disarm”

Door Chime

Door Chime sound: “Ding-Dong” x 1

Door Bell

Door Bell sound: “Ding-Dong” x 4

When arming with fault in system

Voice prompt: “Fault in system please check system status”

Entry time countdown

“Beep” sound

Exit time countdown

“Beep” sound

Pre-alarm (Outdoor sensor)

Voice Prompt: “Outdoor sensor is triggered please check!”

•  You can change the volume of the indication voice sound between High, Medium and Low through the Control Panel. 

 

The factory default volume is set to Medium, please refer to your control panel for details.

Power Supply

The Siren is powered by AC power; plug the Siren into the power socket to activate the Siren. The Siren will enter normal operation mode.

SRV-23B-ZBS and SRV-23B-ZBSR models have a rechargeable battery inside that serves as backup when the Siren is unplugged from AC 
power. The battery will be charged automatically when the Siren is plugged. It takes about 72 hours to fully charge the battery.

Low Battery Detection (SRV-23B-ZBS / SRV-23B-ZBSR Only)

After AC power failure, the Siren will transmit a Low Battery signal to The Control Panel when low battery voltage is detected. To restore 
battery, re-plug AC power into the power socket. After 12 hours, the Siren will transmit a low battery restored notification to the Control Panel.

AC Failure Detection 

Whenever the Siren is removed from the power socket, the siren will transmit an AC fault signal to the coordinator to notify the situation. 
The Siren will then switch to its internal battery for power supply.

When the Siren is plugged in again on the power socket, it will send an AC power restore signal to the coordinator.

Supervision

The Indoor Siren will transmit a supervision signal to report its condition regularly according to user setting. The factory default interval is 
30 minutes. The user can also press the Function Button once to transmit a supervision signal manually.