4
NookBox
Installation Guide
Glass/Break Detector
LED Indicator
• The LED indicators are inside the front cover and only visible when activated.
• Red LED: The Red LED activates when:
» Tamper Switch is activated.
» Learn/Test button is pressed.
» Glass break detected under Test Mode, Low Battery or Tamper open condition
(The Red LED does not light up when glass break is detected during normal operation)
• Green LED
The Green LED activates when glass break is detected under Test mode.
Getting Started
1 Insert the battery to power on the device.
2 Put the Control Panel into learning mode, refer to panel manual for detail.
3 Press the Learn/Test button once to transmit learn code to panel.
4 Refer to panel manual to complete learning process.
5 Refer to panel manual to complete the learning process.
Sensitivity Adjustment
The Glass Break Detector sensitivity can be adjusted using the two dip switches.
Adjust the sensitivity to change detector range.
Sensitivity
Dip Switch 1
Dip Switch 2
Detection Range
Maximum
OFF
OFF
8m
Medium
OFF
ON
5m
Low
ON
OFF
3m
Minimum
ON
ON
1.5m