Used for remote connetion access point

Nmas-cloud-service connection

Nmas LD host a cloud service. nmas LD can be accesed with web browser on 
local network.

Factory settings for connecting parameters:

SSID: nmas_network

Password: NMAS_Secrets

Security: WPA/WPA2

For accessing data on nmas LD, user has to be on same network. Easiest way 
to do this is to use wireless ”nmas_network”. 

nmas LD unit connects 

automatically to this network if it is properly set-up

. Pre-configured nmas-

wireless creates this network automatically. 

Nmas-wireless units can be:

Mobile phone

Wireless 3G/4G modem

Customer wlan (need configuration)

Special access method (wired-to-wireless)

Local network

Page 27

Picture 29: Local network

Summary of Contents for nmas Simple

Page 1: ......

Page 2: ...mas Software Components 10 LD View 10 View 10 Analysator 11 Configurator 11 Signal processing 11 Analog to digital converter 11 High frequency measurement AD converter 11 Low frequency measurement AD...

Page 3: ...ions of nmas Simple 30 Configuring nmas Simple 30 Connectors 31 Connector pin out 32 Start measurements on nmas Simple 33 Start remote connections on nmas WR optional 33 Configurating nmas Simple 33 R...

Page 4: ...t or human damage Wrong settings can lead to false signal scaling disinformation or might cause machine failures Please use professionals for configuration changes Manufacturer recommends twisted and...

Page 5: ...ase contact your local distributor for support Manuals and user info can be found from manufacturer site http nmas nome fi Manufacturer of the nmas software and hardware is Nome LTD Lummintie 9 90460...

Page 6: ...ebase data This data is described as signal in nmas Signal is sample of data during limited time frame Signal is used for further analysis and can be stored for later analysis Signal is typical for ac...

Page 7: ...gnals as desired Please note that some software level figures have to be specially added to nmas and are not included in standard user interfaces Warning and Alarm Nmas warnings and alarms are always...

Page 8: ...is is usually not desired since it can lead to very high amount of data storage Usually at least one direction of level passing should be set to values higher than 10 In typical condition monitoring s...

Page 9: ...inside unit to enable characteristic value outputs SU uses Ethernet or radio for communication Unit can be configured for different measurements Configuration is stored in LD LD Local Data Local Data...

Page 10: ...l data storage long time data storage remote access database manipulation and big data analysis In small installations nmas server is usually not needed Nmas Software All nmas softwares need Java 7 or...

Page 11: ...gnals All high frequency signals in one unit are measured at the same time When using tacho it is also measured simultaneously with signals All high frequency signals are also measured continuously in...

Page 12: ...and acquire data on multiple levels For analog signals first processing is usually done in nmas sensor unit Unprocessed analog signal is usually also send periodically for database storage Stored valu...

Page 13: ...tion sensors 1 piece tachometer with cable 1 piece adjustable magnetic base for tachometer 1 piece nmas user manual 1 piece nmas View user manual Carrying case Carrying case is used to carry and stora...

Page 14: ...IP 67 Exterior dimensions L x W x D 569 x 425 x 215 22 4 x 16 73 x 8 46 nmas Simple unit Small and easy to carry waterproof case with IP 67 rating Page 14 Picture 10 nmas simple unit dimensions Pictu...

Page 15: ...gh quality sensors With top exit connector AC192 With top exit connector AC192 Sensitivity 100 mV g Dynamic range 80 g peak Voltage source 18 30 VDC With side exit connector AC194 Page 15 Picture 12 A...

Page 16: ...cables provided with nmas device are high quality cables Cables are color coded for easy installation Cable material Black Polyurethane Max temperature 121 C 250 F Cable diameter 6 mm 245 in Connector...

Page 17: ...t accelerometer MH112 Base for top exit accelerometer MH112 Pull strenght 14 kg 30 lbs Mounting 1 4 28 integral stud Max temperature 80 C 176 F Magnetic base for side exit accelerometer MH128 Base for...

Page 18: ...sor Tacho comes with a mounting bracket and reflective tape stripes Illumination Visible Red Laser Class 2 On target indicator Green led on wire end cap Operating range Up to 7 6 meters 25 feet Power...

Page 19: ...t height and angle for the tachometer Magnetic base stand has ON OFF switch to switch the magnet on or off Holding power 60 kg Base size 60 x 50 x 55 mm Weigth 1 4 kg Vertical arm 12 mm dia x 170 mm l...

Page 20: ...required remote connetion no configuration nmas cloud no configuration Runnning nmas software does not require admin privileges if Java and Java webstart support is installed All software is download...

Page 21: ...and alarm limit configurations OK Select Start Stop When control display is visible and measurements are started automatically after 30 seconds unless one press of Stop display button Measurements ca...

Page 22: ...imple Start display button color is green when measurements are ongoing Page 22 Picture 22 Ongoing measurements when Start display button is green Picture 21 Press Start display button to start measur...

Page 23: ...red and blue indicate warning and alarm status and if sensor is connected Color markings green yellow and red indicate warning and alarm level passings Color Meaning Measuremet is between limits Warni...

Page 24: ...the result list main screen will display system info This screen shows connetion information Unit can be accessed with wlan0 addresses in local network In Picture 24 the ip address is http 192 168 43...

Page 25: ...change the name of the nmas device in this screen Trend Pushing right button in the main screen displays selected channels trend Local displays trend screen displays trend chart with limits and the av...

Page 26: ...wireless network Unit connects automatically as a client to predefined nmas wireless network nmas_network This connection is used for the remote display or remote connections nmas wireless creates loc...

Page 27: ...urity WPA WPA2 For accessing data on nmas LD user has to be on same network Easiest way to do this is to use wireless nmas_network nmas LD unit connects automatically to this network if it is properly...

Page 28: ...l network is used in larger measurement network Larger network is usually equipped with nmas server for data and configuration management Nmas server hosts a cloud service Depending on network configu...

Page 29: ...ividual access parameters Connection parameters are set by nmas distributor Customer specified web page is created for all remote connections This page has direct links and related information for acc...

Page 30: ...e 10 kHz Visibility level of figures signal 1 vRMS 1 BIAS 3 Warning level 4 5 mm s for vRMS Alarm level 11 0 mm s for vRMS Warning and alarm limits are based to ISO10816 3 These are general guide rule...

Page 31: ...ensor channels are color coded and match with color coded cables Connector assignment Conn 1 m12 plug A coded Accelerometer Voltage 1 CH 1 Green Conn 2 m12 plug A coded Accelerometer Voltage 2 CH 2 Bl...

Page 32: ...ture 34 m12 D coded pinout Connector pin out Power supply m12 plug A coded Pin1 GND Pin2 GND Pin3 24 VDC IN Pin4 24 VDC IN Pin5 Cable shield Accelerometers Voltage m12 plug A coded Pin1 Signal IEPE Pi...

Page 33: ...nder measurement 4 Connect tacho cable optional 5 Connect power supply 6 Measurements start after 30 seconds and new data is visible on nmas LD screen Start remote connections on nmas WR optional 1 At...

Page 34: ...mponents via domestic waste as they contain electronic components that must be disposed of in the proper manner Please dispose of the unit and individual components in accordance with local regulation...

Page 35: ...or 31 Contacts 34 D Data 6 9 12 Display 10 20 Disposal 34 F Figure 6 Frequency 11 I Interface 6 L Local network 27 M Magnetic base 17 Main screen 21 Measurement 6 23 P Pin 32 R Remote connection 28 Re...