SUGGESTED INSTALLATION

NTG40 

NOMAD TRANS-FLO™

The suction pipe size should be at least 38mm 

 

(1 – 1/2") diameter or larger if highly viscous  
material is being pumped. The suction hose 
must be non-collapsible, reinforced type as 
the NTG40 is capable of pulling a high vacuum. 

 

Discharge piping should be at least 32mm 

 

(1 – 1/4"); larger diameter can be used to reduce  
friction losses. It is critical that all fittings and 

 

connections are airtight or a reduction or loss of pump  
suction capability will result. 

Every pump location should have an air line large 
enough to supply the volume of air necessary to 
achieve the desired pumping rate.

Unnecessary elbows, bends and fittings should be 
avoided. Pipe sizes should be selected so as to keep 
friction losses within practical limits. All piping should 
be supported independently of the pump.

Expansion joints can be installed to aid in absorbing 
the forces created by the natural reciprocating action 
of the pump. Flexible connections between the pump 
and rigid piping will also assist in minimizing pump 
vibration. A surge suppressor should be installed to 
protect the pump, piping and gauges from surges and 
water hammer. 

When pumps are installed in applications involving 
flooded suction or suction head pressures, a gate 
valve should be installed in the suction line to permit 
closing of the line for pump service. 

The NTG40 can be used in submersible applications 
only when both wetted and non-wetted portions are 
compatible with the material being pumped. If the 
pump is to be used in a submersible application, a 
hose should be attached to the pump’s air exhaust 
and the exhaust air piped above the liquid level. 

5

PERFORMANCE
NTG40 METAL  
PTFE-FITTED

Flow rates indicated on chart were determined by pumping water.

For optimum life and performance, pumps should be specified so that daily operation parameters 

will fall in the center of the pump performance curve.

Height...............................442 mm (17.4")
Width ...............................391 mm (15.4")
Depth ...............................285 mm (11.2")
Est. Ship Weight .......Aluminum 17 kg (38 lbs)

316 S.S. 26 kg (57 lbs)

Ductile Iron 22kg (49 lbs)

Air Inlet ................................ 13 mm (1/2")
Inlet ................................. 38 mm (1-1/2")
Outlet ............................... 32 mm (1-1/4")
Suction Lift ........................ 2.74 m Dry (9')
 

8.53 m Wet (28')

Displacement/Stroke ......... 0.53 l (0.14 gal.) 

1

Max. Flow Rate ................ 235 Ipm (62 gpm)
Max. Size Solids .................. 4.8 mm (3/16")

1

Displacement per stroke was calculated at 4.8 

bar (70 psig) air inlet pressure against a 2 bar 
(30 psig) head pressure.

Example:

 To pump 94.6 lpm (25 gpm) against  

a discharge pressure head of 2.7 bar (40 psig)  
requires 4.1 bar (60 psig) and 51 Nm

3

/h (30 

scfm) air consumption. (See dot on chart.)

Caution: Do not exceed 8.6 bar (125 psig) air 

supply pressure.

Summary of Contents for NTG40 TRANS-FLO

Page 1: ...NTG40 NOMAD TRANS FLO O P E R A T I O N M A N U A L AIR OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company ALUMINUM Models DUCTILE IRON Models 316 STAINLESS STEEL Models...

Page 2: ...e for all applications The information provided is the best thinking available regarding chemical compatibility The guide however does not provide a recommendation 2 Always wear safety glasses during...

Page 3: ...FI P Polypropylene P Polypropylene TGN Garlock NEOBACKED K Kynar 5 CenterBlock TGE Garlock EPDMBACKED PU Polyurethane A Aluminum TGV Garlock VitonBACKED MTF MildSteel P Polypropylene PU Polyurethane 1...

Page 4: ...alve Seat The removable seats provide the ball valves a site to check 7 Discharge Manifold Process fluid exits the pump from the discharge port located on the discharge manifold at the top of the pump...

Page 5: ...ulated at 4 8 bar 70 psig air inlet pressure against a 2 bar 30 psig head pressure Example To pump 113 6 lpm 30 gpm against a discharge pressure head of 2 7 bar 40 psig requires 4 1 bar 60 psig and 25...

Page 6: ...ications involving flooded suction or suction head pressures a gate valve should be installed in the suction line to permit closing of the line for pump service The NTG40 can be used in submersible ap...

Page 7: ...h pump and out air exhaust 5 Check type of lubricant being used ISO 15 5 wt recommended Pump runs but little or no product flows 1 Check for pump cavitation slow pump speed down to match thickness of...

Page 8: ...7 EXPLODED VIEW RUBBER DIAPHRAGMS NTG40 NOMAD TRANS FLO EXPLODED VIEW PTFE DIAPHRAGMS...

Page 9: ...04 5000 03 N04 5000 02 22 Clamp Band Large 2 N04 7330 08 N04 7330 03 N04 7330 08 23 Clamp Band Small 4 N04 7100 08 N04 7100 03 N04 7100 08 24 Discharge Manifold 1 N04 5021 01 N04 5021 03 N04 5021 02 2...

Page 10: ...NTG40 RUBBER FITTED NTG40 NOMAD TRANS FLO 9...

Page 11: ...08 N04 7330 03 N04 7330 08 23 Clamp Band Small 4 N04 7100 08 N04 7100 03 N04 7100 08 24 Discharge Manifold 1 N04 5021 01 N04 5021 03 N04 5021 02 25 Inlet Manifold 1 N04 5080 01 N04 5080 03 N04 5080 0...

Page 12: ...NTG40 NOMAD TRANS FLO NTG40 PTFE FITTED 11...

Page 13: ...1645 W Park Ave Suite 200 Redlands CA USA 92373 909 798 9532 A JDA Global Company...

Reviews: