![Nokia RM-57 Service Manual Download Page 282](http://html.mh-extra.com/html/nokia/rm-57/rm-57_service-manual_1699439282.webp)
Appendix A: RF Troubleshooting
Nokia Customer Care
Company Confidential
Copyright
©
2005 Nokia. All rights reserved
A-64
•
Connect the probe to C7529 (or C7582)
•
The frequency of the VCTCXO should be quite exactly 38.4 MHz and level about 0.5 - 0.9 Vpp.
Example of the correct VCTCXO output signal is presented in figure
3.3.5.1 VXO-voltage ok? (=Vdig).
•
Measurement can be done with an oscilloscope and a probe
•
Connect the probe to C7560 (or C7526, C7513)
•
VXO-voltage should be about 2.5 V
3.3.5.1.1 C7560, C7513, C7526 and C2214 ok?
•
Check that components are in place and solder joints are ok
•
Disconnect the power supply from the phone and use an ohmmeter to find out if the VXO-line
is short-circuited to the ground. If short-circuit is found replace C7560, C7513, C7526 and
C2214. If replacing does not help then go to the next steps.
3.3.5.1.2 Replace Retu
3.3.5.1.3 Replace Hinku (N7500) or Vinku (N7501) or VCTCXO (G7501) or all three components
3.3.5.2 BB AFC-voltage ok?
•
See section
3.3.5.3 Replace VCTCXO G7501
3.4 GSM (GMSK) modulation spectrum ok?
•
GSM transmitter has to be active before measurements. Procedure is explained in section
“Transmitter troubleshooting”.
•
Measurement can be done with a GSM transmitter tester or other GSM communication tester.
Settings have to be done according to the 3GPP specifications. Modulation spectrum
measurement is possible to perform also with a spectrum analyser, but in this case
measurement settings have to be done manually.
•
Attach the phone to the product specific test jig and the RF-test device to the RF-coupler.
Coupler attenuation should be also taken into account during measurements.
-
Set TX Data Type to “Random” in Phoenix
-
Enter correct “Centre frequency” to the spectrum analyser (see section “Frequency
mappings”) and “Span” should be set to 2 MHz. “RBW” and “VBW” should be set to 30 kHz.
-
Select a correct attenuator in the spectrum analyser and set “reference level offset” according
attenuation between the phone and the spectrum analyser.
-
Enter “Sweep time” at least to 2.5 s.