Appendix A: RF Troubleshooting
Nokia Customer Care
Company Confidential
Copyright
©
2005 Nokia. All rights reserved
A-7
2.1 RF-BB interface (ST_CDSP_RF_BB_IF_TEST)
RF_BB_IF test (86) tests the functionality of the RAP3G/HINKU/VINKU serial interface & reset lines. If this
test fails, it means that there’s a problem programming Hinku and or Vinku and all of the following
tests cannot give correct data.
Tested signals: VBAT_ASIC, VDIG, VREFRF01, VXO, RFBUSDAT, RFBUSCLK, RFBUSENA, RXRESETX, TXRESETX
Error code for this self test is given in format:
•
0xyy, 0xzz
,where 0xyy, 0xzz part is the total error code:
0xyyzz
Incorrect version number
read from the RX_IC
(0x0001)
YES
Incorrect version number
read from the TX_IC
(0x0008)
YES
Propable
cause:
Solder problem/faulty RAP
Other possible reasons:
-
Solder problem/faulty
Hinku
AND
Vinku
-
Problem with RXRESETX
AND TXRESETX
RX_IC is not reset correctly
(0x0002)
YES
TX_IC is not reset correctly
(0x0010)
YES
NO
NO
Propablecause:
Solder problem/faulty RAP
Other possible reasons:
Solder problem/faulty
Hinku AND Vinku
VXO (VDIG)
voltage
OK?
YES
VXO (VDIG) voltage OK?
YES
NO
NO
Propable
cause:
Problem in RETU or in
VDIG between route
RETU & HINKU & VINKU
Is RXRESETX signal
OK?
NO
YES
Propablecause:
Solder problem/faulty
HINKU
Other possible reasons:
Problem in VDIG between
RETU & HINKU
Propable
cause:
Solder problem/faulty RAP
Other possible reasons:
Short circuit under HINKU/
Faulty HINKU
NO
ST_CDSP_RF_BB_IF_TEST
Continue to
_CDSP_RF_BB_IF_TEST
LURE PAGE_2
ST
FAI
NO
Incorrect version number
read from the RX_IC
(0x0001)
YES
Incorrect version number
read from the TX_IC
(0x0008)
YES
Propable
cause:
Solder problem/faulty RAP
Other possible reasons:
-
Solder problem/faulty
Hinku
AND
Vinku
-
Problem with RXRESETX
AND TXRESETX
RX_IC is not reset correctly
(0x0002)
YES
TX_IC is not reset correctly
(0x0010)
YES
NO
NO
Propablecause:
Solder problem/faulty RAP
Other possible reasons:
Solder problem/faulty
Hinku AND Vinku
VXO (VDIG)
voltage
OK?
YES
VXO (VDIG) voltage OK?
YES
NO
NO
Propable
cause:
Problem in RETU or in
VDIG between route
RETU & HINKU & VINKU
Is RXRESETX signal
OK?
NO
YES
Propablecause:
Solder problem/faulty
HINKU
Other possible reasons:
Problem in VDIG between
RETU & HINKU
Propable
cause:
Solder problem/faulty RAP
Other possible reasons:
Short circuit under HINKU/
Faulty HINKU
NO
ST_CDSP_RF_BB_IF_TEST
Continue to
_CDSP_RF_BB_IF_TEST
LURE PAGE_2
ST
FAI
NO
Incorrect version number
read from the RX_IC
(0x0001)
YES
YES
Incorrect version
number read from the
TX_IC (0x0008)
YES
YES
Propable cause:
Solder problem/faulty RAP
Other possible reasons:
-Solder problem/faulty
Hinku AND Vinku
-Problem with RXRESETX
and TXRESETX
RX_IC is not reset
correctly (0x0002)
YES
YES
TX_IC is not reset correctly
(0x0010)
YES
YES
NO
NO
NO
O (VDIG) voltage OK?
YES
YES
YES
YES
NO
NO
NO
Propable cause:
Problem in RETU or in
VDIG between route
RETU & HINKU & VINKU
Is RXRESETX signal OK?
NO
NO
YES
YES
NO
ST_CDSP_RF_BB_IF_TEST
Continue to
T_CDSP_RF_BB_IF_TEST
S
FAILURE PAGE 2
NO
Propable cause:
Solder problem/faulty
HINKU
Other possible reasons:
-Problem in VDIG between
RETU & HINKU
-Problem with RXRESETX
VXO (VDIG) voltage OK?
Propable cause:
Solder problem/faulty RAP
Other possible reasons:
-Solder problem/faulty
Hinku AND Vinku
Propable cause:
Solder problem/faulty
HINKU
Other possible reasons:
Problem in VDIG between
RETU & HINKU
Propable cause:
Solder problem/faulty RAP
Other possible reasons:
-Short circuit under
HINKU/Faulty HINKU
VX