RM-14
Nokia Customer Care
RF Troubleshooting and Manual Tuning
30
COMPANY CONFIDENTIAL
ISSUE 1 11/04
Copyright © 2004 Nokia. All Rights Reserved.
Typical values and limits in Rx Band Filter Response Compensation EGSM900:
Tuning will automatically move to the next band (GSM1800) when you press
“Save & Contin-
ue”
.
GSM1800 band
Repeat the same steps as for the EGSM900 band above.
Typical values and limits in Rx Band Filter Response Compensation GSM1800:
Table 5:
Channel
Input
frequency
[MHz]
Typical value
[dB]
Low limit
[dB]
High limit
[dB]
965
923.26771
+-3
-10
5
975
925.26771
+-1
-5
5
987
927.66771
+-1
-5
5
1009
932.06771
+-1
-5
5
37
942.46771
+-1
-5
5
90
953.06771
+-1
-5
5
114
957.86771
+-1
-5
5
124
959.86771
+-1
-5
5
136
962.26771
+-3
-10
5
Table 6:
Channel
Input
frequency
[MHz]
Typical value
[dB]
Low limit
[dB]
High limit
[dB]
497
1802.2677
1
+-3
-10
5
512
1805.2677
1
+-1
-5
5
535
1809.8677
1
+-1
-5
5
606
1824.0677
1
+-1
-5
5
700
1842.8677
1
+-1
-5
5
791
1861.0677
1
+-1
-5
5