RH-6
Company Confidential
7 - RF Description & Troubleshooting
CCS Technical Documentation
Page 60
Copyright
©
2003 Nokia Corporation.
Issue 1 10/2003
Company Confidential
Press Stop and a window pops up:
Select
'Save values to Phone Permanent Memory'
Press Yes and the GSM1800 TX Power Level Tuning is finished.
TX power level tuning GSM1900
Set operating mode to local mode.
Select
Maintenance
Tuning
TX Power Level Tuning
Wait until the TX Power Level Tuning window pops up.
Connect a
calibrated
power meter to the RF connector of the phone.
Select
Band
GSM 1900
Active Unit
TX
Press Start and a window pops up:
Select Permanent memory, press OK and the window closes.
Select
TX Data Type Random