RH-6
Company Confidential
7 - RF Description & Troubleshooting
CCS Technical Documentation
Page 24
Copyright
©
2003 Nokia Corporation.
Issue 1 10/2003
Company Confidential
GSM1800 TX troubleshooting
Setup for GSM1800 TX troubleshooting
Start the investigations as described in chapter General instructions for TX troubleshoot-
ing “General instructions for TX troubleshooting”.
Set operating mode to local mode.
Select
Maintenance Testing
RF Controls
Wait until the RF Controls window pops up.
Select
Band
GSM 1800
Active unit
TX
Operation mode
Burst
RX/TX Channel
700
TX PA Mode
Free
TX Power Level
5
TX Data Type
Random
The setup should now look like this:
Now the measurement equipment should measure the following output signal from the
phone.
P
out
= +20dBm @ 1747.8MHz
If this is not the case, then go to the next chapter for finding the fault.
Fault finding chart for GSM1800 transmitter
It is useful to use the TXP signal as trigger-signal It is provided at TXP test point.