PAMS
Technical Documentation
NSC/W–1/3
Disassembly & Troubleshooting Instructions
Page 10
Original 11/99
Trouble Shooting
The following hints should facility finding the cause of the problem when the
circuitry seems to be faulty. This trouble shooting instruction is divided in fol-
lowing section.
1. Phone is totally dead
2. Flash programming doesn‘t work
3. Power doesn‘t stay on or the phone is jammed
4. Display information: Contact Service
5. Phone doesn‘t register to the network or phone doesn‘t make a call.
6. Audio fault.
7. Charging fault
The first thing to do is carry out a through visual check of the module. Ensure
in particular that:
a) there are not any mechanical damages
b) soldered joints are OK
Phone is totally dead
This means that phone doesn’t take current at all when the power switch is
pressed or when the watchdog disable pin (X101 pin 11) is grounded.
Used battery voltage must be higher than 3.0 V. Otherwise the hardware of
CCONT (N150) prevents totally from switching.