VIN
CHAPS
10k
1n
PWM
VBAT
GND
CCONT
L_GND
CHARGER
PWM_OUT
TRANSCEIVER
0R22
VCHAR
ICHAR
100k
22k
1u
2A
30V
VCH
VOUT
RSENSE
GND
CCONTINT
MAD
LIM
MAD
Startup Charging
When a charger is connected, the CHAPS is supplying a startup current
minimum of 130mA to the phone. The startup current provides initial
charging to a phone with an empty battery. Startup circuit charges the
battery until the battery voltage level is reaches 3.0V (+/– 0.1V) and the
CCONT releases the PURX reset signal and program execution starts.
Charging mode is changed from startup charging to PWM charging that is
controlled by the MCU software. If the battery voltage reaches 3.55V
(3.75V maximum) before the program has taken control over the charg-
ing, the startup current is switched off. The startup current is switched on
again when the battery voltage is sunken 100mV (nominal).
Parameter
Symbol
Min
Typ
Max
Unit
VOUT Start– up mode cutoff limit
Vstart
3.45
3.55
3.75
V
VOUT Start– up mode hysteresis
NOTE: Cout = 4.7 uF
Vstarthys
80
100
200
mV
Start–up regulator output current
VOUT = 0V ... Vstart
Istart
130
165
200
mA
Battery Overvoltage Protection
Output overvoltage protection is used to protect phone from damage.
The power switch is immediately turned OFF if the voltage in VOUT rises
above the selected limit VLIM1 or VLIM2.
Parameter
Symbol
LIM input
Min
Typ
Max
Unit
Output voltage cutoff limit
(during transmission or Li–
battery)
VLIM
LOW
4.4
4.6
4.8