The setup should now look like this:
Figure 26: RF Control Values
Now the measurement equipment should detect the following output signal of the
phone:
P
out
= +23dBm @ 1880 MHz
If this is not the case, then go to the chapter
GMSK for the troubleshooting
.
EDGE
Select operation mode to the “local”.
Select->Testing -> RF control
In the popup window common values:
Active unit:->TX
Band: ->1900
Operation mode: ->Burst
RX/TX Channel:->661
In the popup window TX control values:
EDGE:->ON
Tx data type:->Alternate
TX PA mode:->High