Nokia Customer Care
Troubleshooting Instructions
Company confidential
NPL-4/5/
Issue 2 05/05
Copyright
© 2005
Nokia Corporation. All rights reserved.
Page 39
-TX Data Type->Random
The setup should now look like this:
Figure 24: RF Control Values
Now the measurement equipment should detect the following output signal of the
phone:
P
out
= +23dBm @ 1747.8 MHz
If this is not the case, then go to the chapter
GMSK for the troubleshooting
.
EDGE
Select operation mode to the “local”.
Select->Testing -> RF control
In the popup window common values:
Active unit:->TX
Band:->1800
Operation mode: ->Burst
RX/TX Channel:->700
In the popup window TX control values:
EDGE:->ON