12. Measure the power levels with a marker.
Take the first measurement from 250 us after the trigger, the second from 750 us, third on 1220 us and
so on in every 500 us until the table is filled.
Figure 66 High burst measurement
13. In the
High Burst
pane, click Calculate.
14. Check that the calculated values are within the limits specified in the following table:
Min
Max
C0-high
-0.5
5
C1-high
-50
50
C2-high
400
900
C0-mid
-0.7
0.7
C1-mid
0
50
C2-mid
400
900
C0-low
-4
4
C1-low
-400
440
C2-low
-10000
15000
RM-91; RM-92
RF Troubleshooting and Manual Tuning Guide
Nokia Customer Care
Issue 1
COMPANY CONFIDENTIAL
Page 7 –53
Copyright © 2006 Nokia. All rights reserved.