CONFIDENTIAL
15
(25)
NPE-4 6310/NPL-1 6310i
Repairhints
Customer Care Europe & Africa
Version 1.0 Approved
SCCE Training Group
Date 15.08.2002
©
NMP 2002
Checked
by:
SCCE Training Group
Approved by:
SCCE
Flowchart - No service
→
→
→
→
no TX
Set Phone to TX -Mode
EGSM 897.4 MHz,
Ch. 37, power level 10.
Set Spectrum Analyzer to
TX EGSM 897.4 MHz, Ch.37
Check TX
EGSM 897,4 MHz
at R656.
Check TX
PCN 1747.8 MHz
at L602.
Check TX I/Q
67.71 kHz signal at
C764 and C766 at
both sides.
Check UEM D200
Check
TXP VDC > 1.8 V
at C760 with
oscilloscope
Check TXC
signal at C761
with oscilloscope.
Check UPP D400
Check UEM D200
Check 26 MHz
at C752.
Check the
following voltages:
VR2 = 2.8 VDC at C294; VR3 = 2.8 VDC at
C602; VR4 = 2.8 VDC at C601;
VR5 = 2.8 VDC at C604; VR6 = 2.8 VDC at
C605; VR7 = 2.8 VDC at C299;
VrefRF01 & VrefRF02 = 1.35 VDC at R726;
VR1A = 4.7 V at R600
Hagar N600
defect.
Check UEM D200
Check 26 MHz
circuit, especially
G740
No Service/
No TX EGSM/PCN
Set Phone to TX -Mode
PCN 1747.8 MHz,
Ch.700, power level 10.
Set Spectrum Analyzer to
PCN 1747.8 MHz, CH. 700
Check TX EGSM/PCN path from
Hagar to X802 antenna connector
for shorts or disconnections.
Probably N840 defect.
OK
nOK
nOK
OK
nOK
OK
nOK
OK
nOK
OK
nOK
OK
nOK
OK