Modular indicator serieS 2800-xxxx

6543.21

5-6 digits
bright red LED display

Power supply:

85..240VAC or
12..32 VDC / 24 VAC

Typical option cards

Alarms cards:

2 relay card, change over
contacts
4 alarm types,
3 relay card, closing contacts
4 I/O-ports

Output cards

0/4..20 mA, 0..10 V
RS-232 or RS-485

Sensor supply:

24VDC,
150 mA

2800 series input and option cards:

Input card contains:

- microprocessor
- bus control
- keys control
- display control

Eight input cards

   2021

   2011

2011-IN

Process input

2021-MU

Multi input

2031-IR

Infrared sensor input

2041-SG

Strain gage measurement

2051-PU

Scaleable frequency indicator

2061-CO

Counter input (max 5 kHz)

2071-RS

Serial input RS232 / RS485

2081-BCD

BCD-input (1-5 digits)

2000-BASE

Base card with power supply

2000-REL2

Alarm card, NO/NC

2000-REL3

Alarm card, Closing contacts

2000-OUT

Output card, U and I

2000-RS

Serial output RS232 or RS485

2000-I/O

4 pcs input /output ports
(60 V / 100 mA)

Summary of Contents for 2800-2071

Page 1: ...1 Manual Model 2800 2071 for serial inputs No 011002 Nokeval...

Page 2: ...4 Case dimensions 4 Configuration 5 Serial protocol SCL 6 Counting check sum 6 Example of control message without BCC 6 XOR function without calculator 7 Non addressable ASCII protocol 7 Display mode...

Page 3: ...signal RS232 or RS485 You may select red or green 6 digit display Serial bus is galvanic isolated from both processor and power supply In configuration stage you can set address Baud rate and what dis...

Page 4: ...nd holding and keys simultaneously for 2 seconds Specified instructions on pages 6 7 Configuration Resetting configuration parameters Some times it is necessary to return indicator parameters to facto...

Page 5: ...ddressable SCL or non addressable ASCII Baud Baud rate selection 300 600 1200 2400 4800 9600 19200 Addr Serial address 0 127 SCL only Bcc Checksum selection ON used SCL only Resp Responce message sele...

Page 6: ...ost significant bit is set If you want to command a device in address 4 the ID byte will be 132 or 84h This is a single byte whose value is 132 do not send individual numbers 1 3 and 2 The command is...

Page 7: ...hand when displaying numerical results the Numerical mode is more flexible TEXT Mode In the Text mode 2071 doesn t process the message in any way The first received message is placed at the leftmost...

Page 8: ...to the leftmost key 1 N pp in Koodi 1 1 2 2 3 4 4 8 If several keys are pressed simultaneously the sum of these codes is returned E g keys and the code is 4 8 C in hexadecimal When no keys is pressed...

Page 9: ...SerialsignalRS 485looplastunitmustbeterminatedwith110ohm resistor Termination can be done on terminal connections or by connectin short cut jumper into following position Fail safe ON Terminator ON Fa...

Page 10: ...type of meter You can change meter with pulse input to meter with current input thermocouple strain gage etc Additional slots Additional cards provide output 4 20 mA alarms serial interface BCD output...

Page 11: ...ion cards Inputcardcontains microprocessor bus control keys control display control Eight input cards 2021 2011 2011 IN Process input 2021 MU Multi input 2031 IR Infrared sensor input 2041 SG Strain g...