31
E
Equipement
Action
Symptoms
Possible cause
Solution
Authorised or professional technical
service
ON/OFF
Check that the ON/OFF key
blinks 1s every 8s
Does not blink
Check connection to electricity grid
Equipment does not get enough voltage
or defective electrical equipment
Replace keyboard or electric box
Press ON/OFF key
Without changes
Press again covering all the key’s surface
with the finger
Defective keyboard
Replace keyboard
Clean up the excess of water of the
keyboard. 20s pause before pressing
the key again
Key blinks once every 0,5s - >Lack
of water level
Fill the bathtub with water
Defective level sensor or without proper
regulation
Regulate or replace the level sensor
AIR
Press key
Press ON/OFF key, backlit in white
Press again covering all the key’s surface
with the finger
Defective keyboard
Replace keyboard
Clean up the excess of water of the
keyboard. 20s pause before pressing
the key again
Key blinks once every 0,5s - >Lack
of water level
Fill the bathtub with water
Defective level sensor or without proper
regulation
Regulate or replace the level sensor
HYDRO
Press key
Key remains in colour white. ON/
OFF key blinks in blue
Fill the bathtub with water
Lack of water level
Level sensor’s led light does not light up
Defective level sensor or without proper
regulation
Regulate or replace the level sensor
Key remains in colour white. ON/
OFF key remains in white
Press again covering all the key’s surface
with the finger
Defective keyboard
Replace keyboard
Clean up the excess of water of the
keyboard. 20s pause before pressing
the key again
Key changes to blue, but water
pump does not start
Check water pump’s electrical connection
Defective electric box or water pump
Replace electric box or water pump
Key changes to blue, water pump
starts,but water does not run
Check electric valve’s electrical connection
Defective electric valve’s jets
Replace electric valve
CROMOTHERAPY
Press key
Key remains in colour white.
Press again covering all the key’s surface
with the finger
Defective keyboard
Replace keyboard
Clean up the excess of water of the
keyboard. 20s pause before pressing
the key again
Key changes to blue or cyan, but
chromotherapy does not start.
Check lights’ electrical connection
Defective box
Replace electric box
MASAGE
Press key
Key remains in colour white. ON/
OFF key blinks in blue
Fill the bathtub with water
Lack of water level
Level sensor’s led light does not light up
Defective level sensor or without proper
regulation
Regulate or replace the level sensor
Key remains in colour white. ON/
OFF key remains in white.
Press again covering all the key’s surface
with the finger
Defective keyboard
Replace keyboard
Clean up the excess of water of the
keyboard. 20s pause before pressing
the key again
Key changes to cyan, magenta
or red, but water pump or blower
does not start
Try functions individually to detect where
the problem is
Defective box
Replace electric box