• The air vent at the front of the appliance must
never be covered or blocked in any way.
• Avoid locating the unit in damp areas.
Electrical Connection
Check that the voltage marked on the product
corresponds with your supply voltage.
WARNING
: Improper use of the grounded plug
can result in the risk of electrical shock. If the power
cord is damaged, have it replaced by a quali
fi
ed
electrician or an authorized service center.
This appliance should be properly grounded for your
safety. The power cord of this appliance is
equipped with a plug which mates with the standard grounded
outlets to minimize the possibility of electrical shock.
Do not under any circumstances cut or remove the
ground prong from the power cord supplied. For
personal safety, this appliance must be properly
grounded.
This appliance requires a standard 220-240 Volt AC ~50Hz
electrical ground outlet. Have the wall outlet and circuit chec-
ked by a quali
fi
ed electrician to make sure the outlet is pro-
perly grounded. When a standard 2 pins wall outlet is encoun-
tered, it is your responsibility and obligation to have it replaced
with a properly grounded 3 pins wall outlet.
The cord should be secured behind the appliance and not
left exposed or dangling to prevent accidental injury.
The appliance should always be plugged into its
own individual electrical outlet which has a voltage
rating that matches the rating label on the appliance.
This provides the best performance and also
prevent overloading house wiring circuits that could
cause a
fi
re hazard from overheated. Never unplug
the appliance by pulling the power cord. Always
grip the plug
fi
rmly and pull straight out from the
receptacle. Repair or replace immediately all power cords that
have become frayed or otherwise
damaged. Do not use a cord that shows cracks or
abrasion damage along its length or at either end.
When moving the appliance, be careful not to
damage the power cord.
Electrical fuse protection of at least 10 amperes must be provi-
ded. If the socket is no longer
accessible once the appliance has been built -in,
suitable measures must be taken during electrical
installation to ensure that the appliance can be
disconnected from the mains.
Do not use your appliance with an extension cord
unless this cord has been checked and tested by a
quali
fi
ed technician or service person. The extension
cord must be a VED-Listed, 3-wire grounding
extension cord that has a grounding plug and outlet
and that the electrical rating of the cord is 220-240
volts and at least 10 amperes.
Reversing the Door Swing
of Your Appliance
Should you desire to reverse the opening direction, please
follow the instructions below.
1.
Close the glass door, and remove the
decoration plug 2. Unscrew the top hinge pin
3 and lower hinge pin 8. Be careful to
support the glass door with hands to prevent it
dropping after removing the pins. (Figure 1&2)
2.
Pull down to remove the glass door and place
it on a padded surface to prevent scratching it.
3.
Remove the right top hinge plate 4 by unscrewing the
four screws 1 and get the left top hinge plate 6 from the plastic
bag that includes the instruction manual then install it at the
designated position on the opposite side.
(Figure 1)
4.
Remove the lower hinge plate 7 by
unscrewing the four screws 9. Then turn it
around and re
fi
t it on the opposite side.(Figure
2)
5.
Turn around the glass door 180° and re
fi
t the
hinge pin 3&8 through the top hinge plate 6
Screw
1.
Decoration Plug
2.
Top Hinge Pin
3.
Right Top Hinge Plate
4.
Glass Door
5.
Left Top Hinge Plate
6.
Lower Hinge Plate
7.
Lower Hinge Pin
8.
Screws
9.
Cabinet
10.
Note
: All parts removed must be
saved to do the reinstallation of door.