9
SFP port
The
35
7
10
-48G-4TF provides four 10 Gigabit SFP optical module expansion slots for plugging into
Gigabit SFP modules.
Console port
The Console port is used to connect to the serial port of a computer or other terminal to manage
or configure the switch.
Power socket
The power supply to the switch NX-
35
10-48GP must be 100-240V~ 50/60Hz AC power.
Chapter 2 Hardware Connection
2.1 Connecting RJ45 port
Connect the switch and the RJ45 port of the peer network device with a network cable.
2.2 Connecting SFP Ports
The SFP port of the
NX-3510
-48GP supports only 10 Gigabit fiber modules. It is
recommended to use standard SFP module products.
The process of installing a fiber module on a switch is as follows:
1
、
Grasp the fiber module from the side and insert it smoothly along the SFP port
slot of the switch until the fiber module is in close contact with the switch;
2
、
Confirm the Rx and Tx ports of the fiber module when connecting. Insert one
end of the fiber into the Rx and Tx ports to ensure that the Tx and Rx ends of the
interface are correctly connected, and the other end of the fiber is connected to
another device.
3
、
After power-on, check the status of the corresponding indicator. If the indicator
is on, the link is up. If the indicator is off, the link is down. Check the line and confirm
that the peer device is enabled.
Note:
•
It is not allowed to excessively bend the fiber, and its radius of curvature should be no less
than 10cm ;
•
Ensure the cleanliness of the fiber end face;
•
Please do not look directly into the fiber optic connector with your eyes, as this may cause eye
damage.