15
P
ro
g
ra
m
m
in
g
y
o
u
r
O
rio
n
7
0
0
2
Summary with examples
You can divide your panel heater, towel rails, plug-in lights and other
electrical appliances each with their own RECEIVERS into groups
known as ZONES and give each named ZONE a predetermined plan
or PROFILE. With this the Orion 700 can automatically control up to 100
ZONES and dictate when the appliances in a particular ZONE should
be ON or OFF, in comfort, economy or frost. COMFORT or SET BACK
(ECONOMY) in the case of Panel heaters.
* Only 8 characters can be used to name a zone.
Zone
Receiver Code (examples)
Profiles
“Bedroom1”*
(Bedroom 1)
160 242 134 023
160 045 249 105
(example codes only)
Mon-Sun
“Bathroom”
120 006 129 210
(example code only)
Mon-Sun
“Livingr”*
(Living Room)
160
003 001 009
160
233 004 101
160
023 025 089
(example codes only)
Mon-Fri
Sat-Sun
00
03
06
09
12
15
18
21
24
ON
ON
00
03
06
09
12
15
18
21
24
ON
ON
00
03
06
09
12
15
18
21
24
ON
ON
00
03
06
09
12
15
18
21
24
ON
Summary of Contents for Orion 700