OPERATION
Speed Scrub
t
2001 Electric (01–02)
11
TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
No power.
Tripped building circuit breaker.
Reset breaker.
Faulty extension cord.
Replace extension cord.
Faulty pigtail cord.
Contact Service Center.
Brush motor does not operate.
Faulty brush switch.
Contact Service Center.
Machine circuit breaker has tripped. Clean or replace pad or brush and
reset breaker button.
Rectifier has burned out.
Contact Service Center.
Faulty wiring.
Contact Service Center.
Faulty brush motor.
Contact Service Center.
Carbon brushes worn.
Contact Service Center.
Vacuum motor does not operate.
Faulty vacuum switch or wiring.
Contact Service Center.
Faulty vacuum motor.
Contact Service Center.
Carbon brushes worn.
Contact Service Center.
Little or no solution flow.
Solution flow lever is not activated.
Push solution flow lever forward.
Solution line is clogged.
Remove hose and blow
compressed air through it.
Solution valve is clogged.
Remove valve and clean. Do not
scratch or damage inside of valve.
Solution flow adjustment knob
needs adjusting.
Adjust solution flow knob to
increase solution flow. Turn knob
down to increase flow.
Poor water pick up.
Recovery tank is full.
Empty recovery tank.
Ball float shutoff screen inside
recovery tank is clogged.
Remove screen and clean.
Squeegee is clogged with debris.
Clean squeegee.
Squeegee blades are worn.
Replace squeegee blades.
Squeegee thumbscrews are loose.
Tighten thumbscrews.
Vacuum hose connections are
loose or hose has a hole.
Push vacuum hose cuffs firmly on
connections. Replace hose if
damaged.
Vacuum hose is clogged with
debris.
Remove clogged debris.
Tank gasket is defective.
Replace tank gasket.
Recovery tank water inlet is
plugged. Inlet is located at bottom
of recovery tank.
Empty recovery tank and tilt it
sideways to locate inlet hole,
remove clogged debris.
Drain hose plug is loose.
Tighten drain plug.
Clear recovery tank lid is loose.
Tighten lid.
Vacuum motor is loose.
Tighten down vacuum motor. Do
not over tighten and damage motor.
Safety lights do not work.
Flasher is burned out.
Contact Service Center.