![Nobles Speed Scrub 1701 Plus Operator And Parts Manual Download Page 11](http://html1.mh-extra.com/html/nobles/speed-scrub-1701-plus/speed-scrub-1701-plus_operator-and-parts-manual_1698152011.webp)
OPERATION
11
Speed Scrub
1701 Plus (12–00)
ATTENTION: Do not continue to operate machine
when battery meter is in the red zone, battery
damage will result.
10. On last scrubbing pass, turn off solution switch
just prior to stopping machine. This will allow total
recovery pick up.
11. When solution tank runs dry, drain recovery tank.
(See DRAINING TANKS).
CIRCUIT BREAKERS
The machine is equipped with two circuit breakers to
protect machine from damage. The Main (20amp) and
Brush (35amp) circuit breakers.
If circuit breakers should trip, the breakers will not
reset immediately upon tripping. Determine reason
why breaker tripped, wait a few minutes and reset
(See TROUBLE SHOOTING).
Brush motor circuit breakers will trip due to excessive
overload on pad. Reduce pad pressure or replace pad
if breaker trips. Circuit breakers are located on control
console (Figure 27).
FIG. 27
MACHINE ADJUSTMENTS
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.
ADJUSTING SOLUTION FLOW
To increase or decrease the maximum solution flow,
turn adjustment knob. Adjustment knob is located near
brush lift pedal (Figure 28).
FIG. 28
ADJUSTING PAD PRESSURE
NOTE: On rough surfaces it may be necessary to
reduce brush pressure.
To adjust pad pressure, turn adjustment knob
clockwise to decrease or counterclockwise to increase
pad pressure. Adjustment knob is located below brush
lift pedal (Figure 29).
FIG. 29
ADJUSTING SQUEEGEE LIFT CABLE
To adjust squeegee lift cable, loosen lock nuts and
turn adjustment stem on squeegee cable. Retighten
lock nuts after adjusting (Figure 30).
FIG. 30