OPERATION
14
Quick Clean
1500 (03–00)
4.
Activate pump switch and press vacuum/blower
switch towards vacuum symbol (Figure 35).
FIG. 35
5.
Operate floor tool as normal (Figure 36).
WARNING: Flammable materials or reactive
metals can cause an explosion or fire. Do not pick
up.
FIG. 36
6.
After cleaning, relieve water pressure from tool
before disconnecting hose. Squeeze trigger for
five seconds after turning switches off.
7.
Perform recommended maintenance procedures
(See MACHINE MAINTENANCE).
MACHINE MAINTENANCE
To keep machine in good working condition, follow
machine’s daily, monthly and quarterly maintenance
procedures.
FOR SAFETY: When servicing machine, unplug
cord from wall outlet.
ATTENTION: Machine repairs must be performed
by authorized personnel only.
HOUR METER
Each machine is equipped with an hour meter to
record total hours of pump use. Use meter to
determine when to perform recommended
maintenance procedures and to record service history
(Figure 37).
FIG. 37
DAILY MAINTENANCE
1.
Clean metering tip and flush blue injector tube as
described below:
a.
Fill solution tank with 3 gallons (11L) of clean
water.
b.
Remove metering tip from injector tube and
clean tip. Do not use pointed objects such as
pins and paper clips to unplug tips (Figure 38).
FIG. 38