OPERATION
8
Flood Pumper
t
Plus (02--06)
TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
Poor pick up.
Float shut-off screen is clogged.
Clean screen inside recovery tank.
p
p
Loose drain hose knob.
Close drain valve.
Loose recovery tank cover.
Tighten down cover with latches.
Damaged hose.
Replace hose.
Vacuum motor does not
t
Unplugged cord.
Plug cords into separate grounded circuits.
operate.
Faulty switch or loose wiring.
Contact Service Center.
Tripped building circuit breaker.
Reset circuit breaker.
Defective vacuum motor.
Contact Service Center.
Discharge pump does not
t
Unplugged cord.
Plug cords into separate grounded circuits.
g p
p
operate.
Faulty pump float switch.
Contact Service Center.
Tripped building circuit breaker.
Reset circuit breaker.
Defective vacuum motor.
Contact Service Center.
Discharge pump operates
continuously.
Airlock has formed in discharge pump
inlet.
Connect open end of discharge hose to
vacuum intake hose connector and turn on
machine.
Faulty pump float switch.
Contact Service Center.
SPECIFICATIONS
Model
Flood Pumper
t
Plus
LENGTH
762 mm (30 in)
WIDTH
508 mm (20 in)
HEIGHT
889 mm (35 in)
WEIGHT
41 Kg (90 lbs)
RECOVERY TANK CAPACITY
60.5 L (16 gal)
VACUUM HOSE
4.5 m (15 ft) x 38 mm (1.5 in)
DISCHARGE HOSE
7.6 m (25 ft) x 38 mm (1.5 in)
FLOOR WAND WIDTH
330 mm (13 in)
DISCHARGE PUMP
115 volt, 1/3 hp, 8.7 psi/.6 bar, 10 amp
DISCHARGE PUMP FLOW RATE
113 L (30 gal) per minute
VACUUM MOTOR
120 volt, 3--stage, 1.6 hp, 10.7 amp,1242 watts
SEALED WATER LIFT
3048 mm (120 in)
POWER CORD LENGTH
15 m (50 ft)
TOTAL POWER CONSUMPTION
120V, 17 A, 2040 W (Use Separate Circuits)
DECIBEL RATING AT OPERATOR’S EAR, INDOORS ON CARPET
80dB(A)