OPERATION
Viper
R
Upright Vacuum Cleaner (06–03)
8
Blinking Orange Light = Full Bag or Air
Obstruction. Replace bag or remove air
obstruction in vacuum hose.
Blinking Red Light = Brush Obstruction or
Brush Height set too low (Amp. overload).
Remove brush obstruction or readjust brush
height.
FIG. 10
To reset sensor system, turn power switch off and then
back on again.
NOTE: The vacuum motor is also protected by an
internal thermal overload sensor. If motor temperature
gets too high, the thermal sensor will shut off motor.
Sensor will automatically reset when motor cools.
WAND OPERATION
The machine is equipped with a “ready to use” wand
and crevice tool.
Contact local distributor for Optional Tool Kit #604802
Kit includes: Upholstery Tool and Dusting Brush.
1.
Stand machine upright. When upright, the power
to the brush motor automatically shuts off.
ATTENTION: When using the wand, keep machine
upright to prevent possible carpet damage.
2.
Detach wand from retainer clip and attach crevice
tool located on carrying handle (Figure 11).
FIG. 11
3.
Activate ON/OFF switch.
WARNING: Do Not Pick Up Flammable Or
Toxic Materials, Burning Or Smoking Debris.
The wand’s hose expands up to 2.4m (8 ft) in
reach (Figure 12)
FIG. 12
MACHINE MAINTENANCE
To keep machine in good working condition, simply
follow machine’s daily, weekly and quarterly
maintenance procedures.
FOR SAFETY: When servicing machine, unplug
cord from wall outlet.
DAILY MAINTENANCE
(Every 4 Hours of Operation)
1.
Check filter bag for fullness, replace bag as
needed. Do not reuse paper bags. Inspect optional
cloth bag for tears or holes, replace if damaged.
2.
Remove entangled debris from brush.
3.
Inspect vacuum hose for damage and clogged
debris.
4.
Inspect power cord and strain relief for damage.
Replace if necessary.
5. Wind power cord around cord hooks rather than
loosely looped over handle.
6.
Clean machine housing with an all purpose
cleaner and damp cloth.
WEEKLY MAINTENANCE
(Every 20 Hours of Operation)
1. Remove secondary filter and tap or blow off dust
build–up, filter is located below filter bag. Do not
clean with water. Replace filter if needed
(Figure 13).