53
Fault
Cause
Elimination
Lift pressure too low
Slide valve get stuck
Break up, cleaning
Oil pore jam
Break up, cleaning
Vibration
Pressure up too slowly
Slide valve get stuck
Break up, cleaning
Exhaust not enough
Exhaust enough
Vibration
Pressure up too slowly
Slide valve get stuck
Break up, cleaning
Exhaust not enough
Break up, cleaning
Liquid level less than
normal
Flooding valve poor regulated
Fine-tune
Noise
Flooding valve poor regulated
Fine-tune
Glide face abrasion
Replace flooding valve
Leak (Outside)
O ring old or damage
Replace O ring
Enactment pressure
too low
Spring bad
Replace spring
Valve base bad
Adjust or replace flooding valve
Leak (inside)
Valve base bad
Amend valve base surface
Enactment pressure
too high
Valve get stuck
Break up, cleaning
(
2
)
Hydraulic pump fault diagnosis (See List 2-12
)
List 2-12
Fault
Cause
Elimination
Liquid
displacement
too
small
Liquid level too low
Infuse liquid to normal
Pipe or filter jam
Clean or replace
Pump pressure too low
● Lining slice bad
● Brace bad
● Seal, lining sleeve seal or
spacer ring badness
Replace
Flooding valve regulated
abnormal
Regulate to normal by
manometer
Air in system
● Retighten pipe beside oil inle
● Infuse liquid
● Replace pump seal
Running noise
Suction pipe bad or filter jam
Check pipe or repair filter
Oil inlet side loose or air
leakage
Tighten loose connecting
Oil viscidity too high
Replace normal viscidity oil to
adapt running
tempdrature
Bubble in liquid
Exhaust air and prevent air
Oil leakage of pump
Pump seal or other airproof ring
bad
Replace
Pump failure
Replace
Summary of Contents for FE4P50N