![Noble UH30-E Installation, Operation And Service Manual Download Page 17](http://html1.mh-extra.com/html/noble/uh30-e/uh30-e_installation-operation-and-service-manual_1697856017.webp)
07610-004-45-09-D
12
PROGRAMMING
CHEMICAL
FEEDER PUMPS
INSTRUCTIONS
INSTALLATION
To access the programming mode, the machine must be ON and "READY" (between
cycles).
On the timer board, press and hold both the MOVE and ENTER buttons simultaneously
for two seconds.
The PROGRAM (PGM) light and light A will illuminate.
Once in the programming mode, the MOVE button is used to scroll between
the programming categories and the ENTER button is used to select the
category.
Press the MOVE button to move the solid light to the desired location of FILL, RINSE
AID, or DETERGENT. Please note that options A, B, C, D, E, and F are not adjustable
outputs.
Press the ENTER button for the chosen category. Now, the (PGM) light will illuminate
along with lights corresponding to the time values for the chosen category. The
ACCEPT light will blink.
The PROGRAM light will illuminate.
To change the value of a parameter, use the MOVE button to illuminate the light next
to the time option (time is measured in seconds). In the time categories, each second
in use will light up. To deselect the option, press ENTER and the light will go off, press
ENTER again and it will illuminate. Once you have set your time category, press the
MOVE button until the ACCEPT light illuminates and press ENTER. This will save the
changed parameters and exit the programming mode.
To change any other values, you will have to return to the programming mode. To
revert back to a previous setting, you must return to that option and change the
parameter back to the previous setting.
Once in the programming mode, if there have been no keypad inputs for approximately
two minutes, the system will automatically exit out of the programming mode. Any
changes to parameters will be lost when the programming mode is automatically
exited. The wash and drain cycles are not adjustable.
All time adjustments are in seconds. Refer to the chart for adjustable outputs.
TIMER PROGRAMMING BOARD
NOTICE
PGM
A
B
C
D
E
F
G
H
ACCEPT
TIME IN SECONDS
8
4
2
1
0.8
0.4
0.2
0.1
MOVE
ENTER
G = Detergent
H = Rinse-aid