07610-004-26-29-E
TROUBLESHOOTING
21
PROBLEM
POSSIBLE CAUSE
REMEDY
Wash water is not
reaching required
temperature.
Faulty wash heater.
Misadjusted/faulty thermostat(s).
Wash thermometer is defective.
Check element for continuity; if open, replace heater.
Verify operation and setting of thermostats; replace if necessary.
Replace thermometer.
Doors will not close
completely.
Improper spring tension.
Obstruction in door channel.
Doors are not square with frame.
Adjust spring tension as required by loosening (not removing) spring bolt
nuts and adjusting the tension. Tighten nuts back when done.
Remove the obstruction.
Adjust the frame to accommodate the doors.
Water leaks at the
wash pump.
Wash pump seal defective.
Petcock or pump drain (if
equipped) not shut/tight.
Loose hoses (hose clamps) on the
wash pump.
Replace the seal.
Close or tighten.
Tighten the hose clamps.
Will not rinse during
autocycle.
Defective rinse solenoid.
Faulty
fi
ll microswitch.
No water to the machine.
Repair or replace the rinse solenoid as required.
Replace microswitch.
Verify that there is water at 20±5 PSI connected to the machine.
Dishes are not
coming clean.
Machine temperatures are not up
to the minimum requirements.
No detergent/too much detergent.
Solid dispenser canister is empty.
Verify that incoming water, rinse water and wash water match the required
temperatures as listed on the machine data plate.
Adjust detergent concentration as required for the amount of water held
by the machine.
Replace the canister.
Summary of Contents for HT-180 HH
Page 2: ......
Page 3: ...i...
Page 29: ...07610 004 26 29 E PARTS 22 TOP MOUNTED CONTROL BOX ASSEMBLY 30 28 29 25 22 21 26 33 34 36 1...
Page 36: ...07610 004 26 29 E PARTS SIDE MOUNT MECHANICAL TIMER CONTROL BOX 29...
Page 38: ...07610 004 26 29 E PARTS HOOD ASSEMBLY 31 1 5 4 2 3 6 7 10 8 9...
Page 50: ...07610 004 26 29 E 43 Y STRAINER INCOMING OUTLET PLUMBING ASSEMBLIES PARTS...
Page 62: ...07610 004 26 29 E 55 460 VOLT MACHINE TRANSFORMER MOUNTING BOX PARTS...
Page 63: ...07610 004 26 29 E 56 PARTS EXHAUST FAN CONTROL OPTION...
Page 71: ...07610 004 26 29 E ELECTRICAL SCHEMATICS 64 NOBLE HT 180 HH UNIVERSAL TIMER 460V 60HZ 3 PHASE...
Page 72: ...07610 004 26 29 E 65 NOBLE HT 180 HH 208 230V 60HZ 1 3 PHASE ELECTRICAL SCHEMATICS...
Page 73: ...07610 004 26 29 E 66 ELECTRICAL SCHEMATICS NOBLE HT 180 HH 460V 60HZ 3 PHASE...
Page 74: ...07610 004 26 29 E ELECTRICAL SCHEMATICS OPTIONS 67 DOOR INTERLOCK OPTION...
Page 75: ...07610 004 26 29 E 68 ELECTRICAL SCHEMATICS OPTIONS EXHAUST FAN HOOKUP DRAIN QUENCH OPTIONS...