FF01/Rev.01/EN
5.
General Specifications
Test Specification
UL508/EN60947-5-1/EN60947-5-5
Rated Operating Voltage (Ue)
Rated Operating Current
Resistive Load (DC-12) 24 V DC 0.5 A
※
UL, TUV certified rating
Rated Insulation Voltage (Ui)
36 V DC
Rated Impulse Withstand Voltage
2.5 kV
Sealing
Front panel: IP65 (IEC 60529)
Pollution Degree
3
Short-Circuit Protection Device
g
G
10A
Conditional Short-Circuit Current
1000 A
Ambient Operating Temperature
-25°C to +60°C (no freezing)
Ambient Storage Temperature
-45°C to +80°C (no freezing)
Operating Force
Push to lock: 10.8 N
Pull to reset: 8.5 N
Turn to reset: 0.13 N
・
m
Minimum force to achieve direct opening
action of all break contacts
15 N
Minimum travel including travel beyond
the minimum travel position
3.0 mm
Maximum travel of actuator
4.5 mm
Contact Resistance
50 mΩ maximum (initial value)
Insulation Resistance
100 MΩ minimum (500 V DC megger)
Overvoltage Category
II
Operation Frequency
600 operations/hour
Shock Resistance
Durability: 1,000 m/s
2
Malfunction: 150 m/s
2
Vibration Resistance
Durability: 10 to 500 Hz half amplitude: 0.35 mm, acceleration: 50 m/s
2
Malfunction: 10 to 500 Hz half amplitude: 0.35 mm, acceleration: 50 m/s
2
Electrical Life/ Mechanical Life
Electrical Life/ Mechanical Life:100,000 operations
Minimum (resistive load), 6050 times
Minimum (inductive load (DC-13))
Recommended Fixing Nut Mounting
Torque
785 mN
・
m
Soldering
390°C within 4 seconds
Effective Panel Thickness
Effective panel thickness of 0.8 to 4.5 mm
(Effective panel thickness range with a nameplate or switch guard of 0.5 to 3.0 mm)
* UL, TÜV certified rating
・
UL/ TÜV certified rating: 24 V DC, 0.5 A (DC-13)
Minimum applicable load (reference value): 5V DC 1 mA
(Usage conditions and load types may affect the allowable operating range.)