- 11 –
SL50
User guide – 33-60-022-000
1.10 Choice of languages
You can configure the
SL50
in one of these six available languages : French, English, Italian,
Spanish, German and Dutch.
-
Using the keys
and
, select the
CONFIG
channel,
-
Press
Ent
key until the list of Sub-channels
valid alarm
,
language
and
lighting
appears,
-
Successively
press
Ent
key to select the chosen language,
-
Press
Ent
to validate,
Exit the setting menu by maintaining pressure on
Ent
or wait 10s until the
SL50
automatically
exit the menu. The new setting is saved in memory
1.11 Zero setting of the daily log
The channels
daily log
and
total log
are at your disposal on your display.
You will use the daily log to count the number of nautical miles completed during a sailing leg.
The value is kept in memory when the power supply of your installation is cut off. Resetting the
daily log
channel to zero will allow you to count the number of nautical miles of the following
sailing leg.
Zero setting procedure of the daily log
-
using the keys
and
, select the channel
daily log
,
-
Press
until the log is set to 0
.
The
total log
indicates the number of nautical miles completed since the installation of your
depth-finder log interface
. Only a complete initialisation of your
depth-finder log interface
allows to reset the
total log
to zero. It is performed by initialising the
surface
speed
channel.