USING 

1.1  PRESENTATION 

The HR masthead unit is a measuring instrument for wind speed and direction. It is connected 
to  the  TOPLINE  bus  of  your  installation.  Equipped  with  high  quality  ball  bearings  and 
mechanical  elements  of  precision,  the  HR  masthead  unit  guaranteed  qualities  of  a  reliable, 
precise and sensitive sensor. 

The support equipped with a TOPLINE bus cable, is not provided with the masthead unit. 

ARCHITECTURE OF THE INSTALLATION 

  

 

 

 

 

 

 

 

IMPORTANT 

-

  Do not dismantle masthead unit parts 

-

  Read this user guide entirely before starting the installation. 

-

  The electrical connection of the TL25 on the TOPLINE bus must be carried out with 

the terminal box 90-60-121. Only use TOPLINE bus cable of the type 20-61-001. 

-

  Any intervention on the TOPLINE bus must be carried out with the installation power 

switched off.
 

 Cable TOPLINE

 20-61-001

GND

DATA black

12VDC white

Figure 1

log depth interface

90-60-450

       log
speedomètre

depth

connecting box

90-60-417

NMEA -

NMEA +

 input NMEA

nke

TL 25

16.85

BOAT SPEED

 APP WIND A

105-

KNOTS

DEGRES

10.50

DEPTH

METERS

Summary of Contents for 90-60-369

Page 1: ...Zi de Kerandr Rue Gutemberg 56700 HENNEBONT FRANCE www nke marine electronics com HR Masthead unit Product reference 90 60 369 USER GUIDE and INSTALLATION GUIDE...

Page 2: ...5 1 6 TECHNICAL SPECIFICATIONS 5 1 7 DIAGNOSTIC OF 1ST LEVEL TROUBLESHOOTING 5 2 CALIBRATION 6 2 1 CALIBRATION OF THE WIND VANE 6 2 2 CALIBRATION OF THE ANEMOMETER 7 3 INSTALLATION 8 3 1 LIST OF ACCES...

Page 3: ...unit ARCHITECTURE OF THE INSTALLATION IMPORTANT Do not dismantle masthead unit parts Read this user guide entirely before starting the installation The electrical connection of the TL25 on the TOPLINE...

Page 4: ...vated The upper alarm is activated when the display is higher than the programmed threshold The lower alarm is activated when the display is lower than the programmed threshold To cancel the alarm of...

Page 5: ...eck the troubleshooting table below Problem Possible causes and solutions The Topline installation does not detect the masthead unit The bus cable is not or is badly connected to the terminal box chec...

Page 6: ...offset This offset ranges between 0 and 180 or between 0 and 180 It is the reference of your wind vane in relation to the axis of the support stem Before the start of a calibration we recommend that y...

Page 7: ...ibration at port 2 2 2 Setting procedure of the calibration coefficient 1 Select the calib coef sub channel of the apparent wind speed channel 2 Enter the new calibration coefficient and validate usin...

Page 8: ...iate plate 3 1 LIST OF ACCESSORIES 25 meter masthead unit cable with plate and support 90 60 509 35 meter masthead unit cable with plate and support 90 60 562 TOPLINE terminal box 90 60 121 Windmill 9...

Page 9: ...rt 2 Coat the interior face of the plate with sealing putty 3 Attach the support using tow screws M5X35mm not provided 4 Run the cable inside the mast preferably in a sleeve The entry and exit of the...

Page 10: ...sents itself we advise you to dismount the masthead unit from its support during wintering periods in order to increase the lifespan of the bearings If you set down the wind vane because of dismasting...

Reviews: