14
15
Connect a single modem/phone/fax line into surge-
protected “IN” outlet on the back panel of the UPS unit.
Connect from “OUT” outlet to the equipment with
another modem/fax/phone line cable.
Step 7.
Disable and enable EPO function:
Keep the pin
1 and pin 2 closed for UPS normal operation. To
activate EPO function, cut the wire between
pin 1 and pin 2.
Step 8.
Turn on the UPS:
Press the ON/Mute button on
the front panel for two seconds to power on
the UPS.
Step 9.
Install software:
For optimal computer system
protection, install UPS monitoring software
from the CD you got with the UPS. When your
computer restarts, the monitoring software
will appear as an orange plug icon located in
the system tray, near the clock.
It’s in closed status
for UPS normal
operation.
NOTE:
The battery charges fully during the first five hours
of normal operation. Do not expect full battery run capability
during this initial charge period.
Network/Fax/Phone surge port:
Step 6. Network connection
Button operations
Operations
5.1
5
ON/Mute Button
•
Turn on the UPS: Press and hold ON/Mute button for
at least 2 seconds to turn on the UPS.
•
Mute the alarm: After the UPS is turned on in
battery mode, press and hold this button for at
least 5 seconds to disable or enable the alarm
system. But it’s not applied to the situations when
warnings or errors occur.
•
Up key: Press this button to display previous
selection in UPS setting mode.