background image

FAULT-FINDING

Fog not produced:

Check that the "ready" indicator is illuminated. If not wait

until the "heating" indicator is extinguished and the

"ready" indicator illuminated.

If neither indicator illuminated, check that the mains plug

is fully inserted into the mains socket and that the mains

socket is functional.

Check that the appliance is heating correctly (the case

will feel warm to the touch)

Check that the there is fog fluid in the tank.
Pump is excessively noisy:

Check that there is fog fluid in the tank.

If this does not solve the problem, clean the appliance as

described in the "Maintenance" section.

PAT TESTING

When used in a workplace, this product must be safety-

tested yearly by a qualified electrician (PAT Tested) in

order to comply with the Electricity at Work Regulations. 

If hired out, it must be PAT tested prior to each hire.

We recommend that it is PAT tested regularly when

used in a domestic environment.

 Page 6

Summary of Contents for NJ421

Page 1: ...NJ421 High output fog machine Creates fog effects 900 W temperature controlled heater 1 litre fluid tank Radio remote control Page 1...

Page 2: ...and understand the hazards involved Children should be supervised to ensure that they do not play with the luminaire Not for use in a domestic environment For indoor use only Do not place on carpet o...

Page 3: ...ficial fog may cause irritation to the eyes and throat especially in persons with respiratory ailments A risk assessment should be carried out before use taking into consideration the amount of artifi...

Page 4: ...onnecting via an extension lead make sure that the lead is rated at 6 Amps or more and that it is fully unwound Allow the fog machine to warm up This takes about 5 minutes When warmed up the ready ind...

Page 5: ...ar solution to clean fog fluid residues from the heating block If the mains lead is damaged it must be replaced by the manufacturer or an authorised service centre If the mains plug needs to be replac...

Page 6: ...ase will feel warm to the touch Check that the there is fog fluid in the tank Pump is excessively noisy Check that there is fog fluid in the tank If this does not solve the problem clean the appliance...

Page 7: ...charge to the end user When replacing an existing appliance with a similar new appliance your retailer may take the old appliance for disposal TECHNICAL SPECIFICATION Dimensions 250 140 180 mm Weight...

Page 8: ...attempts made to service or modify the unit then the warranty will be rendered void The product you buy may sometimes differ slightly from illustrations This warranty is in addition to and does not af...

Reviews: