Instruction manual
OCM Pro CF
page 70
OCM Pro CF - Rev. 09 as of 07.06.2016
®
9
Parameter Setting
9.1 Setting Basics
The transmitter in the background operates with the settings which have been
entered at the beginning of the parameter setting. Just after you finish the new
entries, the system asks to accept the new values.
If “yes”, it is needed to enter the PIN code.
2718
If prompted enter this number into the OCM Pro.
Important Note
The PIN code protects against unauthorized access.
Never give the PIN code to any unauthorised persons. Even do not leave the
code next to the equipment or write it down on it.
If a faulty code has been entered three times the parameter mode will be abort-
ed. The unit will proceed to operate using the values set earlier. If the correct
code has been entered the modified parameters are accepted and the system
resets. This reset will take approx. 20-30 seconds.
Besides having the option to save modified parameters or to reject any modifica-
tion by pressing >No< at the end of the parameter setting procedure, it is possi-
ble to jump back to the previous level using the >Back< function. This enables
the user to modify settings which might have been forgotten without the need to
buffer previously modified settings.
Fig. 9-1
Screen at end of parameter setting
If parameter settings are not going to be modified but just verified by selecting
each parameter, there will be no request at the end of the dialog.
Modifications concerning language, units, contrast and display brightness do not
require the PIN code as these settings influence just the way of representation
and not measurement or the output of measurement values.