Example 2:
1 Level
2 Level water-ultrasound
3 Level pressure internal
4 Level 2-wire probe
Fig. 9-133 Menu with water-ultrasonic, pressure and 2 wire probe
If 1 or 2 sensor types were selected only this will be indicated respectively
H
echo profile
Active on level measurement via water-ultrasonic from the bottom and air-
ultrasonic from the top.
Fig. 9-134 Selecting level measurement echo profile
Fig. 9-135 Display echo profile with sensor type POA/OCL
This graphic enables the service personnel to assess the quality of the echo sig-
nal in the measured acoustic path. Ideally the first peak (reflections from the in-
terface between water and air) is very narrow, steep and high, all further peaks
(double and multiple reflections caused by the echo signal moving back and
forth between the interfaces water/air and water/ground) are lower and wider.