31 Diagnosis h-Sensors
Fig. 31-1
Diagnosis menu h-sensors
This menu has a relation to the menu >Applications</>h-Sensors<. Depending on the type and
number of sensors defined here the sections are indicated in the corresponding colours.
F
c
See chapter „23.2 Setting Parameters in h-Sensors Menu“
The Diagnosis indicates the current level in an unchangeable state. The adjustment height can
be set and must be confirmed with OK (Fig. 31-1). The adjustment height is equal to the offset
and is normally specified when the h-sensor parameters are set.
Depending on which sensors are selected the value, the calibrated value or the raw value are
indicated.
•
Value:
issued value
•
Calibrated value:
corrected used value
•
Raw value:
real measured value
Furthermore the ring-down behaviour can be viewed by using the “Diagnosis” button.