Nitto APS-125 Instruction Manual Download Page 5

4

INSTRUCTIONS FOR

THIS TOOL

About Your Tool

WARNING

 Wear protective glasses and a dustproof mask

Operation generates chips and dust particles, etc. 

which may cause eye and/or respiratory injury. 

Always use PPE (Personal Protective Equipment) 

for eye and respiratory protection.

● 

Always turn off the air supply and disconnect the 

air supply hose beforehand whenever replacing 

Abrasive Papers.

● 

Be sure to keep hands clear of moving parts.

● 

After mounting Pad, hold the Palm Orbital 

Sander under a steel workbench or safety place 

and run it for at least one minute.

Make certain no one is within the operating direction 

of the Pad. If the Pad is defective, improperly 

mounted or the wrong size and speed, this is the 

time it will usually fail.

● 

Air pressure at the sander inlet must not exceed 

0.6 MPa.

● 

Always replace damaged, bent or severely worn 

Pads.

Do not use a Pad that has been subjected to an 

Abrasive Paper failure.

1. USAGE

This tool is for sanding workpieces using Abrasive 

Paper.

WARNING

This tool is not designed for water sanding. 

Never use for water sanding.

2. CHECK THE CONTENTS OF THE PACKAGE

Check the contents and make sure that the tool 

does not have any damage which may have 

occurred during transportation. The contents should 

correspond to the list as 7-8 pages parts list. In case 

of damage/missing parts, please contact the sales 

agent from whom you purchased the tool.

3. AIR SUPPLY

3-1. Air Pressure

Adjust air pressure with the air regulator to the 

appropriate level for the pneumatic tool used. 

Air pressure that is too low will stop the tool from 

operating at full capacity.

Air pressure that is too high may cause damage to 

the tool.

3-2. Air Line

 (Fig.1)

Use a 9.5 mm (3/8”) I. D. connecting hose between 

the compressor and the tool.

Drained water, etc., if flown into the tool, could 

cause tool failure. Install an air filter between the 

compressor and the tool.

ג͚

ͺ͑͟͵͟

Fig. 1

3-3. Lubrication

Install an oiler between the compressor and the tool.  

Use the machine oil ISO VG-10. Failure to lubricate 

as required may result in damage to the tool. Use of 

oil that is too thick will reduce the performance of the 

tool.

4. PREPARATION

WARNING

Always turn off the air supply and disconnect 

the air supply hose.

4-1.  How to assemble Dust Connection Hose and 

Bag (APS-125SV, APS-150SV)

Insert one end of the Dust Connection Hose to the 

exhaust of the tool and tighten securely. Connect 

another end of the Hose to the Dust Connection Bag 

or dust collector.

4-2.  How to install Dust Collector (APS-125CV, 

APS-150CV)

Securely install the hose end of Dust Collector (under 

operation by the customer) on the hose mounting 

port of this tool. The hose mounting port diameter is 

26mm. If it dose not fit with the hose port diameter of 

the Dust Collector correctly, use the Adapter.

Summary of Contents for APS-125

Page 1: ...acuum Type Model APS 125CV APS 150CV Central Vacuum Type PROFESSIONAL TOOL Keep the manual handy so you can use it whenever necessary Original Instructions Speci cations Model APS 125 APS 150 Maximum...

Page 2: ...euillez demandez votre foumisseur de manuel instruction en langue locale Spanish Por favor cantacte con su distribuidor para el manual de instrucciones en espa ol Portuguese Por favor pessa ao seo age...

Page 3: ...y in place other parts are free from damage and that the tool runs as it should Check that moving parts are properly adjusted for positioning and tightened that parts are free from damage and properly...

Page 4: ...sed your tool directly Do not detach label or nameplate from tool When a label nameplate gets damaged worn or becomes missing contact the sales agent through which you have purchased your tool or Nitt...

Page 5: ...parts list In case of damage missing parts please contact the sales agent from whom you purchased the tool 3 AIR SUPPLY 3 1 Air Pressure Adjust air pressure with the air regulator to the appropriate l...

Page 6: ...ly align Misalignment of those holes will decrease the performance of dust collection Abrasive Paper Fig 3 6 HOW TO OPERATE THE TOOL 6 1 Start and Stop To Start Hold the tool and press the Throttle Le...

Page 7: ...oring the tool in a location subject to high humidity If the tool is left as it is used residual moisture on the inside can cause rusting Before storing and after operation oil the tool at the air inl...

Page 8: ...not attempt to service or repair the Tool Do not take the Tool apart Contact an authorized Nitto dealer for all service and repair of the Tool Improper service and repair can cause accidents and serv...

Page 9: ...Bearing 6000ZZ 1 24 TQ04656 Bent Retaining Ring BG 10 1 51 TQ04764 Spacer 52 38 0 5 1 25 TB08658 Housing Ass y 1set 26 TQ12695 Label Nitto 1 27 TQ12699 Label Model Number 1 54 TQ06276 Label Lubricati...

Page 10: ...rer i Authorised Compiler n he Community t NITTO KOHKI U S A Inc 4525 Turnberry Drive Hanover Park IL 60133 U S A Tel 1 630 924 9323 Fax 1 630 924 0303 http www nittokohki com index html Unit 21 Empir...

Reviews: