![Nitto APS-125 Instruction Manual Download Page 5](http://html1.mh-extra.com/html/nitto/aps-125/aps-125_instruction-manual_1696609005.webp)
4
INSTRUCTIONS FOR
THIS TOOL
About Your Tool
WARNING
●
Wear protective glasses and a dustproof mask
Operation generates chips and dust particles, etc.
which may cause eye and/or respiratory injury.
Always use PPE (Personal Protective Equipment)
for eye and respiratory protection.
●
Always turn off the air supply and disconnect the
air supply hose beforehand whenever replacing
Abrasive Papers.
●
Be sure to keep hands clear of moving parts.
●
After mounting Pad, hold the Palm Orbital
Sander under a steel workbench or safety place
and run it for at least one minute.
Make certain no one is within the operating direction
of the Pad. If the Pad is defective, improperly
mounted or the wrong size and speed, this is the
time it will usually fail.
●
Air pressure at the sander inlet must not exceed
0.6 MPa.
●
Always replace damaged, bent or severely worn
Pads.
Do not use a Pad that has been subjected to an
Abrasive Paper failure.
1. USAGE
This tool is for sanding workpieces using Abrasive
Paper.
WARNING
This tool is not designed for water sanding.
Never use for water sanding.
2. CHECK THE CONTENTS OF THE PACKAGE
Check the contents and make sure that the tool
does not have any damage which may have
occurred during transportation. The contents should
correspond to the list as 7-8 pages parts list. In case
of damage/missing parts, please contact the sales
agent from whom you purchased the tool.
3. AIR SUPPLY
3-1. Air Pressure
Adjust air pressure with the air regulator to the
appropriate level for the pneumatic tool used.
Air pressure that is too low will stop the tool from
operating at full capacity.
Air pressure that is too high may cause damage to
the tool.
3-2. Air Line
(Fig.1)
Use a 9.5 mm (3/8”) I. D. connecting hose between
the compressor and the tool.
Drained water, etc., if flown into the tool, could
cause tool failure. Install an air filter between the
compressor and the tool.
ג͚
ͺ͑͟͵͟
Fig. 1
3-3. Lubrication
Install an oiler between the compressor and the tool.
Use the machine oil ISO VG-10. Failure to lubricate
as required may result in damage to the tool. Use of
oil that is too thick will reduce the performance of the
tool.
4. PREPARATION
WARNING
Always turn off the air supply and disconnect
the air supply hose.
4-1. How to assemble Dust Connection Hose and
Bag (APS-125SV, APS-150SV)
Insert one end of the Dust Connection Hose to the
exhaust of the tool and tighten securely. Connect
another end of the Hose to the Dust Connection Bag
or dust collector.
4-2. How to install Dust Collector (APS-125CV,
APS-150CV)
Securely install the hose end of Dust Collector (under
operation by the customer) on the hose mounting
port of this tool. The hose mounting port diameter is
26mm. If it dose not fit with the hose port diameter of
the Dust Collector correctly, use the Adapter.