background image

9

Plate D

Min.12

Fig.14

6. HOW TO REPLACE INDEXABLE INSERT

WARNING

● 

Be sure to turn the switch OFF and remove 

the power plug from power supply whenever 

replacing Indexable Insert.

● 

The Indexable Insert and the Holder are much 

heated right after the operation. Always wear 

gloves in handling the Indexable Insert and the 

Holder.

(1) Lay down the Knob with it pulled up. (Fig.15, 16)

(2) Open the Lock Plate with the Knob laid down. 

(Fig.17)

(3) Remove the Indexable Insert Set Screw using the 

Spanner T-15D attached to take off the Indexable 

Insert. (Fig.17)

(4) Mount a new Indexable Insert (including use of 

reverse surface) paying attention to the direction of 

the IndeXable Insert. (Fig.17)

(5) Close the Lock Plate with the Knob laid down and 

lay the Knob aside to lock it. (Fig.18)

PULL

UP

Knob

Fig.15

DOWN

Fig.16

OPEN

Lock Plate

Indexable Insert

Indexable Insert

         Set Screw

Fig.17

CLOSE

PUSH

Fig.18

7. MAINTENANCE AND INSPECTION

WARNING

● 

Be sure to turn the switch OFF and remove 

the  power  plug  from  power  supply  during 

maintenance and inspection.

● 

Perform  periodic  inspection  to  check  for 

loosening of the attachment screws for each 

part. Retighten loose screws as required.

7-1. Replacing the Carbon Brushes

● 

After replacing the carbon brushes, always run 

the unit for at least 10 minutes under no load 

conditions.

Periodically check for wear on the Carbon Brushes, 

because as rectification deteriorates the likelihood 

Summary of Contents for EMB-0307C

Page 1: ...d 99 dB A Load 104 dB A Vibration Level Load Motor 8 1 m s2 Knob 4 9 m s2 Original Instructions Due to continuous product development improvement the specifications and configurations in this document...

Page 2: ...uagen local Italian Per Manuale Istruzioni in lingua locale Vi preghiamo di rivolgervi al rivenditore o distributore Dutch Vraag uw handelaar om een nederladstalige gebruiksaanwijzing Swedish Be er lo...

Page 3: ...tion is unavoidable use a residual current device RCD protected supply Use of an RCD reduces the risk of electric shock 3 Personal safety a Stay alert watch what you are doing and use common sense whe...

Page 4: ...and burns Never touch any moving parts of the tool when running BEFORE OPERATION Inspect tool before use Before using check that screws are securely tightened that any protective cover or guard is sec...

Page 5: ...ne part consult this Manual or contact the sales agent from which you have purchased your tool directly Do not detach label or nameplate from tool When a label nameplate gets damaged worn or becomes m...

Page 6: ...erts Do not use the worn or damaged Indexable Insert If the unit is exposed under sub zero temperature for a prolonged period of time it may take some time to start up This does not mean that the unit...

Page 7: ...the tool at a chamfering level about 0 5 smaller than the desired one Try a test cut Then adjust the tool for accurate chamfering In the case of Mild Steel You can select chamfering levels from 0mm to...

Page 8: ...uptly 3 The workpieces should be fixed as much as possible while working 5 6 Feeding Speed Be sure you should avoid quick feeding or heavy shock Please refer to Table 2 Stainless Steel 3cm sec Mild St...

Page 9: ...ling up If the tool is operated with the dust box filled with the chips it badly affects finishing surfaces shorten the life of Indexable Insert Hold the motor firmly and throw away the chips by openi...

Page 10: ...e surface paying attention to the direction of the IndeXable Insert Fig 17 5 Close the Lock Plate with the Knob laid down and lay the Knob aside to lock it Fig 18 PULL UP Knob Fig 15 DOWN Fig 16 OPEN...

Page 11: ...Fig 19 Correct Wrong The spring is placed incorrectly The lead wire is placed incorrectly Fig 20 8 CONDITION FOR USE Burn out chips suggest that either the feed speed is too slow or the Indexable Ins...

Page 12: ...9 59 58 57 50 51 52 38 37 36 41 81 35 76 77 78 79 80 82 11 EXPLODED DIAGRAM EMB 0307C WARNING This diagram is for your reference only Do not attempt to service or repair the Tool Do not take the Tool...

Page 13: ...Ass y 1set 42 TP16788 Needle Bearing HK0808 1 81 TQ14198 Label Caution 43 TB08530 Gear Ass y 1set 44 TQ13287 Hexalobular Internal Pan Head Tapping Screw 4 x 25 4 47 TQ10280 O Ring S 22 1 No Part No D...

Page 14: ...Loushanguan Road Shanghai 200336 China Tel 86 21 6415 3935 Fax 86 21 6472 6957 www nitto kohki cn NITTO KOHKI SHANGHAI CO LTD Shenzhen Branch 2005C Shenzhen ICC Tower Fuhuasanlu 168 Futian District S...