11
EN
The following settings are available.
Details
Setting value
Default
-
CH NAME
Up to 50 double-byte characters (100 single-byte characters)
If the CH name is changed, the [Installation] settings must be
updated. The CH name is saved in the robot, and is not reflected
in the controller.
-
1
SCREW FASTENING TYPE
SOFT / HARD
SOFT
2
COUNT
0 to 99
4
3
SCREW FASTENING
SPEED
Lv1 to Lv9
Cannot be input if [SCREW FASTENING TYPE] is [HARD].
Lv5
4
TORQUE
1% to 100%
30%
5
INITIAL SPEED
OFF / Lv1 to Lv9
OFF
6
INITIAL SPEED TIME
0 / 0.01 sec to 9.99 sec*
1
0 / 1 to 60000*
2
Cannot be input if [INITIAL SPEED] is [OFF].
0
7
MIDTERM SPEED
OFF / Lv1 to Lv9
OFF
8
MIDTERM SPEED TIME
0 / 0.01 sec to 9.99 sec*
1
0 / 1 to 60000*
2
Cannot be input if [MIDTERM SPEED] is [OFF].
0
9
REVERSE SPEED
Lv1 to Lv9
Lv9
10
SCREW FASTENING
MEASUREMENT LOWER
LIMIT
0 / 0.01 sec to 9.99 sec*
1
0 / 1 to 60000*
2
0
11
SCREW FASTENING
MEASUREMENT UPPER
LIMIT
0 / 0.01 sec to 9.99 sec*
1
0 / 1 to 60000*
2
0
12
WORKPIECE SIGNAL
OFF / ON
OFF
13
WORKPIECE SETUP TIME
0 / 0.1 sec to 9.9 sec
0
14
SCREW FASTENING
OK(PASS) SIGNAL
OFF / ON
ON
15
OK(PASS) OUTPUT TIMING
COUNT FINISHED / AT WORKPIECE REMOVAL
Cannot be input if [WORKPIECE SIGNAL] is [OFF].
COUNT
FINISHED
16
SCREW FASTENING
CONFIRMATION TIME
0 / 0.1 sec to 9.9 sec
Cannot be input if [COUNT RETURN] is [OFF].
0
17
OPERATION OK(PASS)
SOUND
OFF / TYPE1 to TYPE9
TYPE1
18
OPERATION NG (FAIL)
SOUND
OFF / TYPE1 to TYPE9
TYPE1
19
COUNT UP SOUND
OFF / TYPE1 to TYPE9
TYPE1
20
AUTO REVERSE
OFF / ON AFTER TORQUE UP / ON AFTER SCREW FASTENING
MEASUREMENT LOWER LIMIT
OFF
21
REVERSE TIME
0 / 0.01 sec to 9.99 sec*
1
0 / 1 to 60000*
2
Cannot be input if [AUTO REVERSE] is [OFF].
0
22
COUNT RETURN
OFF / ONE COUNT ONLY / MULTIPLE COUNTS
ONE
COUNT
ONLY
23
BIT BRAKE
OFF / ON
ON
24
REFASTENING
PROHIBITED TIME
0 / 0.1 sec to 9.9 sec
1.0 s
25
SCREWDRIVER LED
OFF / RED / GREEN / BLUE / YELLOW / CYAN / MAGENTA /
WHITE
OFF
26
SCREW FASTENING
DIRECTION
RIGHT / LEFT
RIGHT
*1 When the [MEASUREMENT METHOD] of the common settings is [TIME]
*2 When the [MEASUREMENT METHOD] of the common settings is [ROTATION SIGNAL]