background image

4

INSTRUCTIONS FOR

THIS TOOL

About Your Tool

WARNING

 Always turn off the air supply and supply hose 

beforehand whenever replacing Indexable Insert.

 To replace the Indexable Insert after using, do 

not touch with bare hands as the Indexable 

Insert and holder are heated at high temperature.

 Use our original Indexable Inserts.

 Do not use the worn or damaged Indexable Insert.

1. USAGE

This tool is for chamfering workpieces with a 

Indexable Insert.

2. CHECK THE CONTENTS OF THE PACKAGE

Check the contents and make sure that the tool 

does not have any damage which may have 

occurred during transportation. The contents should 

correspond to the list as follows. In case of damage/

missing parts, please contact the sales agent from 

whom you purchased the tool.

AMB-0307

Package Contents

Qty

Check

MINI BEVELER

1

Knob

1

Hex. Socket Screw Key 4

1

Indexable Insert with Hole 12.7

1

Hex. Socket Screw Key 3

1

Hex. Nut M8

2

Hex. Socket Set Screw 8

×

25 Special

2

Spanner T-15F

1

Bushing R3/8

×

NPT3/8

1

Instruction Manual

1

Caution for Use

1

AMBL-0307

Package Contents

Qty

Check

MINI BEVELER

1

Knob

1

Hex. Socket Screw Key 4

1

Indexable Insert with Hole 12.7

1

Hex. Socket Screw Key 3

1

Hex. Nut M8

2

Hex. Socket Set Screw 8

×

25 Special

2

Spanner T-15F

1

Bushing R3/8

×

NPT3/8

1

Instruction Manual

1

Declaration of Conformity

1

Caution for Use

1

3. NAME OF PARTS

4. AIR SUPPLY

4-1. Air Pressure

Adjust air pressure with the air regulator to the 

appropriate level for the pneumatic tool used. 

Air pressure that is too low will stop the tool from 

operating at full capacity.

Air pressure that is too high may cause damage to 

the tool.

4-2. Air Line

 (Fig.1)

Use a 9.5 mm (3/8”) I. D. connecting hose between 

the compressor and the tool.

Drained water, etc., if flown into the tool, could 

cause tool failure. Install an air filter between the 

compressor and the tool.

Air Regulator

Oiler

Air Filter

Compressor

Lubrication

Tool

9.5mm (3/8”) I.D.
Hose

Cupla

Fig. 1

4-3. Lubrication

Install an oiler between the compressor and the tool.  

Use the machine oil ISO VG-10. Failure to lubricate 

as required may result in damage to the tool. Use of 

oil that is too thick will reduce the performance of the 

tool.

Summary of Contents for AMB-0307

Page 1: ...that you may use it properly and safely MINI BEVELER Model AMB 0307 AMBL 0307 PROFESSIONAL TOOL Keep the manual handy so you can use it whenever necessary Original Instructions Speci cations Model AMB...

Page 2: ...or cantacte con su distribuidor para el manual de instrucciones en espa ol Portuguese Por favor pessa ao seo agente ou distribuidor o manual de instrucces ih linguagen local Italian Per Manuale Istruz...

Page 3: ...or guard is securely in place other parts are free from damage and that the tool runs as it should Check that moving parts are properly adjusted for positioning and tightened that parts are free from...

Page 4: ...your tool directly Do not detach label or nameplate from tool When a label nameplate gets damaged worn or becomes missing contact the sales agent through which you have purchased your tool or Nitto K...

Page 5: ...PT3 8 1 Instruction Manual 1 Caution for Use 1 AMBL 0307 Package Contents Qty Check MINI BEVELER 1 Knob 1 Hex Socket Screw Key 4 1 Indexable Insert with Hole 12 7 1 Hex Socket Screw Key 3 1 Hex Nut M8...

Page 6: ...ring is required set the tool at a chamfering level about 0 5 smaller than the desired one Try a test cut Then adjust the tool for accurate chamfering In the case of Mild Steel You can select chamferi...

Page 7: ...the scale of desired angle can align to the Guide Pin 3 Tighten the Hex Socket Head Cap Screws The tool has the limit of chamfering width which depends on a chamfering angle Fig 9 Fig 10 BEVELE R AMB...

Page 8: ...t shorter 6 9 Radius Chamfering By using radius chamfering Indexable Inserts radius chamfering job can be done Radius cutting Indexable Insert is an optional accessory 1 Select the radius chamfering 2...

Page 9: ...DE L NITT OK OH KI MA DE INJ AP AN MIN I Plate B Min 12 Min 300 Fig 18 7 HOW TO REPLACE INDEXABLE INSERT WARNING Always turn off the air supply and disconnect the air supply hose Bear in mind that In...

Page 10: ...moisture on the inside can cause rusting Before storing and after operation oil the tool at the air inlet with machine oil ISO VG 10 and run it for a short time 11 ORDERING SERVICE PARTS For further...

Page 11: ...t attempt to service or repair the Tool Do not take the Tool apart Contact an authorized Nitto dealer for all service and repair of the Tool Improper service and repair can cause accidents and severe...

Page 12: ...06715 Countersunk Flat Head Screw 5 8 1 35 TQ00144 Housing 1 36 TP14030 Pinion 1 37 TP10133 Ball Bearing 609ZZ 2 38 TP14034 End Plate B 1 39 TP10130 Sunk Key 3 3 10 1 40 TP14033 Rotor 1 41 TA9A294 Bla...

Page 13: ......

Page 14: ...d Bangkok Representative Office 38Q House Convent Bldg 7th Floor Unit 7A Convent Rd Silom Bangkok 10500 Thailand Tel 66 2 632 0307 Fax 66 2 632 0308 http www nittobkk com eng_index htm EC DECLARATION...