background image

 

- 7 -

 

3. System Configuration 

 

3.1 Network mode 

Terminals are connected by network and it can be remote 
control.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
                 Figure 3.1 Network Block Diagram 

 
 

Network(TCP/IP) 

Server PC 

Client PC 

Terminal

Lock 

Door Open S/W 

Summary of Contents for NAC-2500+

Page 1: ...NAC 2500 Terminal Installation Guide...

Page 2: ...E mail customer nitgen com URL http www nitgen com Reproduction of part or all of the contents in any form is prohibited other than in accordance with the permissions Product specification can be cha...

Page 3: ...nstallation Environment 6 3 System Configuration 3 1 Network mode 7 3 2 Standalone mode 8 4 Installation 4 1 Fastening the auxiliary plate 9 4 2 Attaching other devices except the terminal 11 4 3 Conn...

Page 4: ...ation guide because the performance can be decreased if the product is installed incorrectly 1 2 Product package Product Pictures Qty Use Terminal 1ea Access Controller Adapter 1ea Power cord 1ea Supp...

Page 5: ...5 4ea Fastening the terminal Bolt 6ea Fastening the rear case Housing 1ea Receptacle cable 5ea Connecting door cable S W CD 1ea...

Page 6: ...d not be exposed outside and it is highly recommended to bury them underground If that is impossible you must obtain the user s consent before installation Power supply should begin after all connecti...

Page 7: ...7 3 System Configuration 3 1 Network mode Terminals are connected by network and it can be remote control Figure 3 1 Network Block Diagram Network TCP IP Server PC Client PC Terminal Lock Door Open S...

Page 8: ...mode One terminal is used independently All settings such as user registration deletion and access control are performed in the terminal alone Figure 3 2 Terminal Block Diagram Locking Device Door Op...

Page 9: ...ices except terminal locking device interphone etc Connect the external cables Fasten the terminal 4 1 Fastening the auxiliary plate Decide where you want to install the product and cut the rear case...

Page 10: ...10 Align the bracket with the hole for wiring as shown Figure 4 2 and fasten it with 6 bolts supported in the packet Figure 4 2 Fastening rear case...

Page 11: ...DC12V 1A or lower Voltage output Fail Safe Secure Electric Strike input DC12V 1A or lower Voltage output Fail Safe Secure Auto Door Maximum Switching Voltage 220V DC 250V AC Maximum Switching Current...

Page 12: ...to the connector Contact output is used when installing on the auto door So make sure to set the terminal JP1 as OPEN The factory default of the terminal JP1 is JUMPER Some locking devices may not ha...

Page 13: ...itoring Door Open 1 GND GND GND COM Open button 2 Door Open button Open button 3 Door Monitoring Monitor 12 24V 4 CONTACT_B VCC 12 24 V 5 COMMON COM 6 CONTACT_A VCC 12 24 V The Relay Boad JP1 Close Co...

Page 14: ...Normal Open Normal Close Door Monitoring Door Open 1 GND COM Open button 2 Door Open button Open button 3 Door Monitoring Monitor 12 24V 4 CONTACT_B Contact 5 COMMON Contact Contact 6 CONTACT_A Conta...

Page 15: ...J45 8PIN UTP 6 RXN 4 3 3 Connecting the power cable Connect 12V adapter to Relay Board J4 Connect 5V adapter ro Main Board J3 NOTICE When you connect extend cable make sure the polarity are correct 4...

Page 16: ...e needs a termimal resistance connect J18 J1 Connection PIN Number Function 1 GND 2 TRX 3 TRX 4 3 6 Wiegand input Main board J9 Wiegand input cannot be used with RF module J9 Conncetion PIN Number Fun...

Page 17: ...17 4 3 7 Normal RF Module Option J9 HID MIFARE EM JP2 5VA R74 R75 0 R72 R73 Open...

Page 18: ...18 4 3 8 SOC RF Module Option J9 JP2 3VA R74 R75 Open R72 R73 0...

Page 19: ...ssemble the terminal with the rear case as shown in Figure 4 3 Figure 4 3 Assebling with rear case Screwing the terminal as shown in Figure 4 4 with the 4 terminal screws supported in the package Figu...

Page 20: ...20 If you did all the procedures described the termimal installation is completed as shown in Figure 4 5 Figure 4 5 Teminal after the installaion...

Page 21: ...ID and fingerprint By default user ID is set to 4 digits long Test the devices including locking device attached to the terminal by performing fingerprint authentication If there s no problem delete...