19
CONNECTING THE POWER SOURCE CABLE
PROHIBITED
!
• The hoist must be efficiently grounded, and an inde-
pendent circuit breaker of the appropriate capacity
must be installed in the power source system.
DANGER
The power source systems of hoists connected to trolleys are as follows:
lnstall a messenger wire ( 0 6 mm steel cable) parallel to the trolley beam.
Hang the power source cable from the messenger wire with cable carriers, and be
careful not to twist the power source cable.
lnstall cable carriers at every 1.5 meters length of the power source cable.
The connections of the Power source cable must only be made at the Hoist,Termi-
nal box and Power source switch. Do not use Power source cables that are lengthe-
ned with connections.
The following power source feeding method can be used in place of the Messen-
ger wire method. Please consult an electrician for the most appropriate method for
your hoist: CABLE CARRIER METHOD,
TROLLEY DUCT METHOD &
TROLLEY WIRE METHOD
GROUND
CONNECTION
1.
1.
2.
3.
Messenger wire
Trolley beam
Power source switch
Cable carrier
Terminal box