background image

PS-570/1

Optical Fiber Studio System

Volume1, 1st edition Ver. 1.0

光コンバージョンシステム

Operating Instructions

取 扱 説 明 書

 Before operating the system, please read this manual 

 thoroughly and remain it for future reference.

Optical Fiber Base Station

ベースステーション

PS-470/1

Optical Fiber Camera Adaptor

カメラアダプター

ご使用の前に、この取扱説明書をよくお読みください。
また、お読みになった後は、大切に保管してください。

Summary of Contents for PS-470

Page 1: ...udio System Volume1 1st edition Ver 1 0 Operating Instructions Before operating the system please read this manual thoroughly and remain it for future reference Optical Fiber Base Station PS 470 1 Opt...

Page 2: ...duct Safety EN61000 6 4 Electromagnetic Interfer ence Emission EN61000 6 2 Electromagnetic Suscepti bility Immunity This product is intended for use in the following Electromagnetic Environments E1 re...

Page 3: ...djustments and Settings System Connection Guide Multi Camera System Connection Guide Outside View and Dimensions Speci cations Front panel PS 470 1 4 6 PS 570 1 9 11 PS 470 1 32 PS 570 1 34 4 31 28 14...

Page 4: ...rts 04 Optical Fiber Camera Adaptor PS 470 1 Main panel HEADSET1 TALLY POWER ON OFF OFF ON INCOM DC 12V IN HEADSET2 OPTICAL FIBER CAMERA ADAPTER MINI MAX MINI MAX MINI MAX MINI MAX MIC H P SIDE TONE I...

Page 5: ...Optical Cable Litium Battery Pack or the DC 12V IN connector INCOM HEADSET DL 400 MIC INCOM Volume Adjust the MIC level and the HEADPHONE level of the HEADSET DL 400 connected to the INCOM HEADSET co...

Page 6: ...PS 470 1 06 Optical Fiber Camera Adaptor PS 470 1 Connector panel GEN LOCK REMOTE L HD SDI SDI IN TC IN TC OUT MADE IN JAPAN TALLY DC OUT IF OUT HD SDI RET OUT...

Page 7: ...Connect with the Optical Adapter Base Unit PS 570 by the Optical ber cable ALC 100M The maximum length of the optical ber cable is 2000 meters Outputs the power DC 12V 2 PIN NC 3 PIN NC 1 PIN GND 4 PI...

Page 8: ...CC 450 i for IKEGAMI RCC 450P for Panasonic RCC 450S for SONY TALLY Lamp Lights up when receiving the TALLY signal from PS 570 It can be turned ON OFF by TALLY Switch on the Main panel PS 570 ON OFF L...

Page 9: ...hts up when the HD SDI signal is received from the Camera Optical Adaptor PS 470 LS Lights up when the Laser signal from the Camera Optical Adaptor PS 470 is received LED OFF When the SD SDI signal is...

Page 10: ...l Adjust the volume of the input output and the side tone of an external 4 wire intercom system connected to the AUX INCOM 4W connector XLR 5 pin Adjust the volume of the microphone the headphone and...

Page 11: ...15 1 2 3 4 5 6 7 8 9 10 15 14 13 12 11 Input the tally signal from a switcher HD D sub 15 pin connector Pin assignment Output the tally signals input from a switcher to other PS 570 1500 Tally Cable C...

Page 12: ...70 ALC 100M 2000M OPT CABLE connector Input the RET signal composite or HD Y from a switcher Input the appropriate signal according to the VF of the camera connected to the CA The input signal is outp...

Page 13: ...tputs the HD SDI or SD SDI signal from the Optical Fiber Camera Adaptor PS 470 Signal format HD or SD is indicated at the Operation status indicator Connect with the DC 12V power supply Connect with t...

Page 14: ...tripod 1 2 Fix the Camera Adaptor PS 470 to the V shoe mount of the camera V PS 470 Optical Fiber Studio System PS 470 1 PS 570 1 PS 470 1 PS 570 1 Make sure to turn o the POWER switch of each unit be...

Page 15: ...OCK REMOTE L RET OUT HD SDI SDI IN TC IN TC OUT MADE IN JAPAN TALLY DC OUT IF OUT HD SDI SD SDI IN Connection PS 470 1 PS 570 1 HD SDI HD SDI video signal connection PS 570 HD SDI SDI OUT VTR BNC HD S...

Page 16: ...EN LOCK REMOTE L RETOUT HD SDI SDI IN TC IN TC OUT MADE IN JAPAN TALLY DC OUT IF OUT HD SDI RET OUT BNC to monitor HDF 700 etc HD SDI return video signal HD SDI RET IN RET HD SDI BNC Connect the retur...

Page 17: ...g the monitor LVM 89W connect the IF OUT monitor interface connector of PS 470 to the MONI IF connector of LVM 89W with the 6 pin cable VC 450 IF OUT 6 pin to LVM 89W return composite video signal TAL...

Page 18: ...lens by cables PROTECH VIF 100BC for SONY PDW 355 PDW 335 etc PDW HDW etc IF OUT 6 pin cable Connection PS 470 1 PS 570 1 GEN LOCK REMOTE L RET OUT HD SDI SDI IN TC IN TC OUT MADE IN JAPAN TALLY DC O...

Page 19: ...I SDI IN TC IN TC OUT MADE IN JAPAN TALLY DC OUT IF OUT GENLOCK Connection PS 470 1 PS 570 1 GENLOCK GENLOCK signal connection GEN LOCK connector GENLOCK reference signal GENLOCK reference signal from...

Page 20: ...OUT VTR TC IN Connect the TC IN OUT to the time code in out connector of the external recording equipment TC IN OUT connector 1 from VTR etc Connection PS 470 1 PS 570 1 TC Time Code signal connectio...

Page 21: ...camera remote cable RCC 450S P REMOTE System Connection PS 470 1 PS 570 1 PS 570 REMOTE REMOTE connector 2 Connect the REMOTE connector of PS 570 to a camera remote controller by the camera remote cab...

Page 22: ...570 1 LANC PS 570 REMOTE REMOTE L connector 2 Connect the REMOTE L connector of PS 570 to a LANC remote controller by the LANC remote cable supplied with the remote controller LANC remote controller L...

Page 23: ...connection GEN LOCK REMOTE L RET OUT HD SDI SDI IN TC IN TC OUT MADE IN JAPAN TALLY DC OUT IF OUT HEADSET1 TALLY POWER ON OFF OFF ON INCOM DC 12V IN HEADSET2 OPTICAL FIBER CAMERA ADAPTER MINI MAX MIN...

Page 24: ...XLR 5S Connect an external 2 wire intercom line to the INCOM 2W connector XLR 3 pin Connect an external 4 wire intercom line to the AUX INCOM 4W connector XLR 5 pin INCOM 2W connector AUX INCOM 4W co...

Page 25: ...y connection IF OUT OPT cable DC OUT connector POWER switch DC PS 570 DC 12V IN DC 12V AC PS 470 Li For DC operation connect an optional DC power supply to the DC12V IN connector of PS 570 and connect...

Page 26: ...DSET Connection PS 470 1 PS 570 1 INTERCOM HEADSET connection DL 400 PS 470 Connect the supplied Intercom headset DL 400 to the HEADSET 1 2 connector of PS 470 1 HEADSET1 TALLY POWER ON OFF OFF ON INC...

Page 27: ...er cable to the OPT cable connector of PS 570 Connect an Optical ber cable optional PROTECH ALC 100M etc to the OPT cable connector of PS 470 PS 470 OPT ALC 100M Connection PS 470 1 PS 570 1 Optical F...

Page 28: ...HEADSET1 HEADSET2 While listening to the operator turn up the two volumes of INCOM MIC and H P gradually so that the voice of the operator and your own voice are heard clearly And turn down or up the...

Page 29: ...d Monitor are light up If it s OK the multi camera system is ready to start recording PS 470 1 PS 570 1 Adjustments and settings GEN LOCK REMOTE L RETOUT HD SDI SDI IN TC IN TC OUT MADE IN JAPAN TALLY...

Page 30: ...CHER OUT Composite or HD Y BNC CABLE TO NEXT PS 570 TALLY IN HD D Sub 15Pin HD D Sub 15Pin HD SDI IN1 BNC CABLE 2W INCOM SYSTEM 2 4 4W INCOM SYSTEM HD SDI IN2 BNC CABLE Remote controller AC AC PS 570...

Page 31: ...P SIDE TONE HEADSET1 HEADSET2 TALLY HD LS Camcorder PS 470 1 Tally Return Power Incom Genlock Remocon HD SDI SD SDI Incom 6 Pin cable VC 450 HEADSET1 TALLY POWER ON OFF OFF ON INCOM DC 12V IN HEADSET2...

Page 32: ...32 Outside dimension unit mm PS 470 1 Outside View and Dimensions Optical Fiber Camera Adaptor PS 470 1 169 IF OUT TALLY 0 8 1 1 9...

Page 33: ...clock Incom Incom XLR 4pin male x2 Tally Tally indicator x2 LED Main panel x1 and Tally Lamp Connector panel ON OFF Selectable x1 Remote Remote 8pin or 10 pin 2 LANC Stereo mini jack 2 5mm Optical ber...

Page 34: ...34 Outside dimension unit mm PS 570 1 Outside View and Dimensions Optical Fiber Base Station PS 570 1 320 215 71 rear 4W I O EXT LINE 4W I O INTERCOM HEADSET...

Page 35: ...pin 2 LANC Stereo mini jack 2 5mm LEMO P N FXW 3K 93C TLM maximum distance Cable Plug 2km with power supplied via ber optic cable to PS470 General Weight approx 3 9kg Dimensions WxHxD 215x71x320 mm Po...

Page 36: ...PS 470 1 PS 570 1 Operating Instructions TM...