background image

OSCNS209-EN 

1/7 

Instruction manual

Electric Actuated Needle Valve

NS NH NP

SP-1401 

Please read this manual before installation and use.

GENERAL 

Compact and lightweight electric actuated needle valve. (linear) 
LAX type actuator has a high quality positioner. 

Valve 

NS  type  For general use 

NH  type  3 piece / For high pressure and high temp. 

NP  type  For Corrosive fluid 

NS 

NH 

 

NP 

PRODUCT CODE 

NS type  

(Linear)   L  A X N S

0  5  U U F 

-

-

 

 

 

(EQ%)    L  A X N S

0  5  U U F  X E

1  5  -

-

NH type  

 

  L  A X N H

0  5  U U T 

-

-

NP type  

 

  L  A X N P

0  1  K K T 

0  1  5  -

-

(1) 

(2)  (3) (4) (5) (6) (7) (8) (9) (10) (11) 

(12)    (13)

(1) Actuator 

LAX 

(2) Valve

NS       
NH       
NP       

(3) Voltage

1 : 100 / 110 V AC 
2 : 200 / 220 V AC 

(4) Sizing code 

0 : Standard 
1 : Light 
2 : Heavy 

(5) Connection 

5 : Threaded End Rc 
1 : JIS 10K 

(6) Body material 

U : SCS14A / SUS316 
K : PEEK 

(7) Trim material 

U : SUS316 
K : PEEK 

(8) Stem packing material 

F : F-PTFE 
T : PTFE 

(9) Cv value 

S : 0.05  

M : 0.13  

L  : 0.34  

H : 0.8  (NP: 1.4) 
X : 2 

(NP: 0.8) 

(10) Flow characteristics 

0 : Linear 

E : EQ% 

(11) Size [mm] 

ex. 15 A    15 

(12) Option 

(13) Operation mode 

Nil : Mode A 

J  : Mode B 

Summary of Contents for Vpro NS

Page 1: ...pe Linear L A X N S 0 5 U U F 0 EQ L A X N S 0 5 U U F X E 1 5 NH type L A X N H 0 5 U U T 0 NP type L A X N P 0 1 K K T 0 1 5 1 2 3 4 5 6 7 8 9 10 11 12 13 1 Actuator LAX 2 Valve NS NH NP 3 Voltage 1...

Page 2: ...MPa 1 MPa Size mm 10 to 15 10 to 15 15 Material Body SCS14A SUS316 PEEK Trim SUS316 SUS316 HCr PLTD PEEK Seat F PTFE SUS316 None Stem seal Packing F PTFE PTFE PTFE Allowable Leak Rate Bubble tight Cl...

Page 3: ...oint it at the time of the order Indication signal 0 mA SHUT 1 mA OPEN External load resistance less than 3 k Common in mode A B Resolution Less than 0 2 Duty cycle 100 200 V AC 100 110 220 V AC 50 30...

Page 4: ...t us if you need to adjust trimmer Terminal board Mode A LAX 070 Adjustment of dead band Adjustment of dead band is useful to prevent hunting of the actuator Turning D B trimmer clockwise increases th...

Page 5: ...ent distortion of the valve ENVIRONMENT Do not install in place where corrosive gas is present or where vibration is heavy 0 5 G or more When radiant heat causes the surface temperature of the control...

Page 6: ...ver put anything on the actuator or make it into a foothold ADJUSTABLE RANGE OF STROKE LAX 030 SHUT by an input signal 4 mA and shipped It is not necessary to adjust the stroke LAX 070 SHUT by an inpu...

Page 7: ...Replace the actuator Rainwater entered the actuator Added high harmonics noise from an inverter Attachment a filter for each inverter maker option Effect of high level noise Use the shielded wire and...