NIP
Pollux GigE Series – 01M / 05M Camera
Page
35
of
56 Manual 1.0
4.9
Imaging Parameter Setting
4.9.1
Exposure Time
Please refer to the camera technical index to acquire the supported exposure time.
The exposure control supports manual mode, single mode and continuous mode.
When setting trigger mode, the single mode and continuous mode are invalid.
When setting single mode or continuous mode, the exposure time will be limited
by Auto Exposure Time Lower Limit and Auto Exposure Time Upper Limit. The time
range should only be set between Auto Exposure Time Lower Limit and Auto
Exposure Time Upper Limit.
Click Acquisition Control in the attribute list. Select Auto Exposure Time Lower
Limit and Auto Exposure Time Upper Limit. Input available parameter to the
numeric field.
Set the running parameter range of the auto exposure time, as shown in Figure 41.
Figure 41.
Exposure Control
4.9.2
Gain Control
Please refer to the camera technical index to acquire the supported Gain Value.
Gain Control supports manual mode, single mode and continuous mode.
Gain Control under these three modes can be shown as follows:
Manual mode:
Set Gain according to the user’s setting value.
Single mode:
Set Gain value automatically according to the target image
brightness.
Set once only.
Continuous mode:
Adjusting Gain continuously according to the target image
brightness
When setting single mode or continuous mode, Gain is limited by Auto Gain Lower
Limit and Auto Gain Upper Limit. Gain Range should only be set between Auto
Gain Lower Limit and Auto Gain Upper Limit.