NIP
Pollux GigE Series – 01M / 05M Camera
Page
13
of
56 Manual 1.0
processes are accessing the camera. You need to stop the live view
and disconnect the camera, or terminate other processes to access
the camera.
•
If the camera status is Not Reachable, the network of the camera is
exceptional and you should check the camera network settings.
Note
: The camera status may be in Use if the camera IP address is conflicted with
other device. Please make sure the IP address is not occupied before setting the
camera IP address.
4.
If the camera status is Free, you can edit its IP address.
1)
Select the IP type as Static IP, DHCP, or LLA.
Figure 6.
Camera Network Parameters Setting (2)
If you set the IP type as Static IP, you can set the IP address, subnet mask,
and default gateway.
You can also edit the camera name in Device User ID field.
Click Save to save the settings.