.13.

There are “L1”, “L2”, “N” and “     ” symbols marked inside the connector ( see 
Figure 4.11), the Line wire must be connected to

L1

and “L2” terminals; the 

Neutral
wire must be connected to

N

terminal; the Earth of grid must be connected  to

  

 ”

(see Figure 4.5).

WARNING:

Please refer figure 4.2 to connect the DC1 and DC2 in the DC terminal of inverter, then 

connect the ground wire of two DC input. The DC wire connected to DC terminals (shown 

in Fig. 4.5) is recommended AWG12-8, and the fuse is KLM-20 of Cooper Bussmann, only

professional can replace it.

The inverter is suitable for both 208V and 204V grid. Please connect the L1, L2 and N in 

the AC terminal, and connect the ground on the ground terminal.The AC wire connected to 

AC terminals (“L1”, “L2” shown in Figure 4.5) is recommended AWG 8, and the fuse is 

KLM-30 of Cooper Bussmann, only professional can replace it.

Damage to the inverter through the use of fuses as disconnecting units in the 
output circuit of the inverter

WARNING:

Damage to the DC Disconnect due to enlarged knockouts
Enlarged knockouts enable moisture to penetrate the DC Disconnect which 
could damage electronic components in the DC Disconnect.

Note:

4.3.2 Connect grid side of inverter

Before electrical connection Please make sure below steps are strictly followed:

a.  Switch the Solar Supply Main Switch (AC) OFF.

b.  Switch the solar panel DC Isolator OFF.

.12.

Before connection, please make sure the polarity of the output voltage of PV 

array matches the

DC+

and

 “

DC-

symbols.

                    

       Maximum 500Voc for

GCI-1K-2G-W-US   GCI-1.5K-2G-W-US   GCI-2K-2G-W-US   

                  

         Maximum 600Voc for

GCI-2.5K-2G-W-US   GCI-3K-2G-W-US   GCI-3.6K-2G-W-US   

GCI-4K-2G-W-US   GCI-4.6K-2G-W-US   GCI-5K-2G-W-US

Warning

Before connecting inverter, please make sure the PV array open circuit voltage

is within the limit of the inverter. Otherwise the inverter could be damaged.

Please don’t connect PV array positive or negative pole to the ground, it could 

cause serious damages to the inverter

Please use qualified DC cable for PV system. 

Figure 4.5 Connection area of inverter

4.3.1 Connect PV input of inverter

4. Installation

4. Installation

Summary of Contents for GCI-2G-W

Page 1: ...angshan Ningbo Zhejiang 315712 P R China Tel 86 0 574 6578 1806 Fax 86 0 574 6578 1606 Email info ginlong com Web www ginlong com Please record the serial number of your inverter and quote this when y...

Page 2: ...d 3 4 LCD 4 Installation 4 1 Select Location for the Inverter 4 2 Mounting the Inverter 4 3 Electrical Connections 5 Start Stop 5 1 Start the Inverter 5 2 Stop the Inverter Contents 1 3 5 5 5 6 7 7 7...

Page 3: ...4K 2G W US GCI 4 6K 2G W US GCI 5K 2G W US Figure 1 1 Bottom side view DC Switch Water drill hole DC input AC input RS 485 Wiring box LCD display 4 buttons LED lights 6 Operation 6 1 Main Menu 6 2 In...

Page 4: ...bol indicates important safety instructions which if not correctly followed could result in serious injury or death Improper use may result in potential electric shock hazards or burns This manual con...

Page 5: ...al equipment is connected 3 The electrical installation must meet all the applicable regulations and standards 4 The inverter must be installed according to the instructions stated in this manual 5 Th...

Page 6: ...e inverter should be considered Adequate ventilation must be provided if the inverter is to be installed in a confined space 9 NOTE Nothing should be stored on or placed against the inverter 300mm 500...

Page 7: ...uld be mounted in a vertical position as shown in Figure 4 2 The steps to mount the inverter on the wall are given as follows 1 Locate the wall studs in the desired location and align the wall mount b...

Page 8: ...e inverter WARNING Damage to the DC Disconnect due to enlarged knockouts Enlarged knockouts enable moisture to penetrate the DC Disconnect which could damage electronic components in the DC Disconnect...

Page 9: ...CD displays the information of INITIALIZING 4 After 30 180 seconds depending on local requirement the inverter will start to generate power The green LED will be on continually and the LCD displays GE...

Page 10: ...ain Menu Pressing the ENTER key locks Figure 6 2 a or unlocks Figure 6 2 b the screen 5 2 Stop the Inverter Figure 6 2 Locks and Unlocks the Screen of LCD b a 17 16 6 Operation 6 1 Main Menu During no...

Page 11: ...The screen will require the password as below The default password is 0010 Please press down to move the cursor press up to select the number 18 6 3 Settings The following submenus are displayed when...

Page 12: ...rd 6 5 Advanced Settings Technicians Only Select Advanced Settings from the Main Menu to access the following options 1 Select Standard 2 Grid ON OFF NOTE To access to this area is for fully qualified...

Page 13: ...l access to the following submenu see Figure 6 12 Figure 6 12 Press the UP DOWN keys to scroll through items Press the ENTER key to edit the highlighted item Press the UP DOWN keys again to change the...

Page 14: ...030V 0100W 040V 0200W Pressing UP DOWN keys to set power curve Pressing ENTER key to move the selected digit to the next from left to right Press the ESC key to save the power curve point see Figure...

Page 15: ...Over DC voltage Over DC bus voltage Under DC bus voltage Grid interference Initialization system fault Over Temperature Ground fault Table 8 1 Fault message and description ILeak FAULT Relay FAULT DCi...

Page 16: ...tor or the service center Please keep ready with you the following information before contacting us 1 Serial number of GCI Single Phase Inverter 2 The distributor dealer of GCI Single Phase Inverter i...

Page 17: ...31 208V 240V 183V 229V 211V 264V Adjustable NEMA 3R 30 208V 240V 183V 229V 211V 264V adjustable NEMA 3R...

Page 18: ...33 208V 240V 183V 229V 211V 264V Adjustable NEMA 3R 32 208V 240V 183V 229V 211V 264V adjustable NEMA 3R...

Reviews: