15
/
15
9. The appliance shall be disconnected from its power source during cleaning or maintenance and when
replacing parts.
10. The A-weighted emission sound pressure level is below 70Db(A).
11. Max. loading of shelves: 195.3kg/m
²,
the deformation
<
1.04cm/m.
12. Inspections and maintenance are required once a year.
13. The ambient temperature and humidity conditions of the show case climate class following the tab below:
Test room
climate class
Dry bulb
temperature
(
⁰
C)
Relative
humidity (%)
Dew point
(
⁰
C)
Water vapour
mass in dry air
(g/kg)
0
20
50
9.3
7.3
1
16
80
12.6
9.1
8
23.9
55
14.3
10.2
2
22
65
15.2
10.8
3
25
60
16.7
12.0
4
30
55
20.0
14.8
6
27
70
21.1
15.8
5
40
40
23.9
18.8
7
35
75
30.0
27.3
NOTE: the water vapour mass dry air is one of the main points influencing the performance
and the energy consumption of the cabinets. Therefore, the order of the climate class in the
table is based on the water vapour mass column. See also Annex B to compare lab and store
conditions.
14.Food should be placed within the load line.