9. The appliance shall be disconnected from its power source during cleaning or maintenance and when

replacing parts.

10. The A-weighted emission sound pressure level is below 70Db(A).

11. Max. loading of shelves: 195.3kg/m

²,

the deformation

1.04cm/m.

12. Inspections and maintenance are required once a year.

13. The ambient temperature and humidity conditions of the show case climate class following the tab below:

Test room

climate class

Dry bulb

temperature

(

C)

Relative

humidity (%)

Dew point

(

C)

Water vapour

mass in dry air

(g/kg)

0

20

50

9.3

7.3

1

16

80

12.6

9.1

8

23.9

55

14.3

10.2

2

22

65

15.2

10.8

3

25

60

16.7

12.0

4

30

55

20.0

14.8

6

27

70

21.1

15.8

5

40

40

23.9

18.8

7

35

75

30.0

27.3

NOTE: the water vapour mass dry air is one of the main points influencing the performance
and the energy consumption of the cabinets. Therefore, the order of the climate class in the
table is based on the water vapour mass column. See also Annex B to compare lab and store
conditions.

14.Food should be placed within the load line.

Summary of Contents for F2DH2080-01

Page 1: ...PRODUCT AND KEEP IT FOR FUTURE REFERENCE Ningbo Wanquan Electrical appliance Company 195 Beixing road Mazhu town Yuyao county Ningbo city Zhejiang province China Table of Contents SHIPPING DAMAGE Gen...

Page 2: ...e and during unloading This equipment has been carefully inspected at factory and the carrier has assumed responsibility for safe arrival If damaged either apparent or concealed claim must be made to...

Page 3: ...possible to its permanent location Check refrigeration lines to see that they are free and no damage has occurred during shipping Check fan blades for free operation 2 1 Leveling Cabinet These merchan...

Page 4: ...t the door should close and seal 2 4 Fan Cycle Switch Hinged doors freezer only The evaporator fan is cycled off upon a door opening by a switch located above each door This reduces the amount of warm...

Page 5: ...809 52 8 1340 Specification Model R2DH2080 01 F2DH2080 01 Classification Refrigerator Freezer Overall size W x D x H inch 52 8 64 x 31 9 64 x 84 7 64 1340 x 809 x 2151 mm 52 8 64 x 31 9 64 x 84 7 64 1...

Page 6: ...z R290 4 94oz Compressor hp 1 4 hp 3 4 hp Cooling Type Forced air Defrost Off cycle Electric heater Insulation Polyurethane Cyclopentane CFC Free Temperature control type Auto Power supply 115V 60Hz 1...

Page 7: ...ON 5 1 Electrical Supply WARNING Equipment MUST be GROUNDED Wiring of the unit is complete when it is shipped from the factory The unit is supplied with a three conductor electrical cord which extends...

Page 8: ...nterior cleaned regularly CAUTION TO AVOID PERSONAL INJURY OR DAMAGE TO ELECTRICAL COMPONENTS ALWTAYS DISCONNECT UNIT FROM MAIN POWTER SOURCE BEFORE SERVICING OR CLEANING 6 1 Cabinet Surfaces Interior...

Page 9: ...ition disconnects the condensing unit only The evaporator fan motor will be energized until the unit is disconnected from the main power source Remove the fasteners to lower the evaporator housing for...

Page 10: ...n17 Blown19 Blown21 Blown23 Blown49 Blue16 Blue18 Blue20 Blue24 Blue50 2 1 2 1 Defrosting Heater Door Switch1 Door Switch2 Blown31 Blown33 Blown35 R2 Blown37 Blue36 Door Heater R3 Blown39 Blue38 R4 Bl...

Page 11: ...R3 Blown39 Blue38 R4 Blown41 Blue40 Capacitor 2 1 Light Switch Blown27 Blown29 Blue34 LED1 LED2 Blown01 Blue02 Blown03 Blue04 115V 60Hz Fuse 20A Blown05 Load Switch Condenser Fan Blown07 12 15 5 6 11...

Page 12: ...2 1 2 1 0 1 M 6 8 4 3 2 1 7 9 Dixell XR04CX Fuse 15A Relay Relay Evaporator Fan M2 3 4 Light Switch M M Blown05 Blown07 Blown09 Blown13 Blown15 Blown27 Blown29 Blue11 Blue06 Blue08 Blue12 Blue16 Blue2...

Page 13: ...self contained display cases Wanquan agrees to repair or exchange at its option the original motor compressor unit only with a motor compressor of like or of similar design and capacity if it is shown...

Page 14: ...or any reason 9 For costs related to shipping or handling of replacement parts 1 If the supply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer or its...

Page 15: ...below Test room climate class Dry bulb temperature C Relative humidity Dew point C Water vapour mass in dry air g kg 0 20 50 9 3 7 3 1 16 80 12 6 9 1 8 23 9 55 14 3 10 2 2 22 65 15 2 10 8 3 25 60 16 7...

Reviews: